82
GEF & GEF-VH Series Fryers
Troubleshooting
8.1
Temperature Control System - continued
Problem
Probable Cause
Corrective Action
FRYER WILL NOT HEAT:
(VH Model Only)
•
Power Light is
ON
•
Selector Switch is in
COOK
position
•
Continuous tone alarm sounding
•
MISSING FILTER
message
displayed on Controller
A. Baffle Filter missing
Check, install Baffle Filter
B. Baffle Filter misaligned
Check, reinstall, or properly align
Baffle Filter
C. Charcoal Filter missing or
misaligned
Check, reinstall, or properly align
Charcoal Filter
FRYER WILL NOT HEAT:
(VH Model Only)
•
Power Light is
ON
•
Selector Switch is in
[COOK]
position
•
Heat Light is
OFF
•
Beeping tone alarm sounding
•
“CLEAN THE EAC”
message
displayed on Controller
A. EAC Cell is excessively dirty
Clean the EAC Cell
B. EAC Cell has bent fins, or shorted
Repair EAC Cell
C. EAC Cell has too many broken
ionizer wires
Replace ionizer wires on Cell
D. Poor connection with Contact
Board; dirty or damaged
Clean contacts, or replace board
E. EAC Power Supply is faulty
Replace Power Supply
F. EAC Shutdown Module is faulty
Replace Module
G. EAC Cell is missing
Install or reinstall EAC Cell
FRYER WILL NOT HEAT:
•
Power Light is
ON
•
Selector Switch is in
[COOK]
position
•
High Limit Light is
ON
A. Power surge
Cycle Power Switch
OFF
for approx 5
secs, return to
[ON]
B. Low oil level
Check level, add oil as needed
C. Contactor is sticking
Check/replace Contactor
D. High Limit Safety Board is faulty
Check/replace High Limit Board
E. High Limit Sensor is faulty, or out of
position
Check, adjust, or replace sensor
E. Controller is faulty
Check/replace Controller
FRYER WILL NOT HEAT:
(VH Model Only)
•
Power Light is
ON
•
Selector Switch is in
[COOK]
position
•
Heat Light is
OFF
•
Constant tone alarm sounding
•
“CLOGGED FILTER”
message
displayed on Controller
A. Charcoal Filter clogged
Replace Charcoal Filter
B. Vacuum Switch requires
adjustment, or is faulty
Adjust Switch, replace if needed
C. Vacuum lines clogged or kinked
Check tubing clean, or remove kinks
D. Fan running too slow
Check voltage
E. Fan clogged with grease film
Clean fan
Содержание GEF-400
Страница 2: ......
Страница 7: ...vi ...
Страница 27: ...GEF GEF VH Series Fryers Overview 16 Ventless Hood VH Models Only 8 9 7 6 5 4 3 2 1 10 11 12 3 1 Control Panel ...
Страница 35: ...24 GEF GEF VH Series Fryers Overview 3 5 Ventless Hood VH Model Only 2 3 8 6 5 7 4 1 ...
Страница 41: ...30 GEF GEF VH Series Fryers Overview Notes ...
Страница 79: ...68 GEF GEF VH Series Fryers Cleaning ...
Страница 101: ...90 GEF GEF VH Series Fryers Parts List 9 4 Fry Pot 1 2 3 4 5 6 7 7 8 8 9 10 10 10 10 11 Not shown 11 11 11 ...
Страница 109: ...98 GEF GEF VH Series Fryers Parts List 9 8 Front Ventless Hood GEF VH Only 4 6 Not shown 5 2 3 8 7 1 ...
Страница 113: ...102 GEF GEF VH Series Fryers Parts List Notes ...
Страница 114: ......