73
GEF-VH Series Fryers Only
Ventless Hood
EAC
7.1.6
EAC Filter Cell Installation
Pin must align with
hole in rear of Filter
Cell.
7.1.7
EAC Filter Operation
Airflow Arrow on
front of Cell
must point
upward.
1
①
ON
The EAC Cell is installed and powered. This is
the only indicator illuminated when the EAC is
functioning normally.
②
WASH/CHECK
These two indicators turn
ON
, to signal a
condition that requires attention. Two (2)
minutes after these lights turn
ON
, a beeping
alarm will sound, the
Heat Light
will turn
OFF
and heating elements are shutdown. The
message
“ERROR ALARM - CLEAN THE EAC”
is
displayed on
OLED Display
③
.
There are various causes for this alarm.
Typically, collection fins in the Cell are
excessively dirty; clean as described in the
following Section.
Other possible causes include; damaged Cell,
poor connectivity (dirty contacts), missing
ionizer wires, faulty wiring, or EAC power
supply malfunction
.
Three LED indicator lights on the Control Panel display the operational status of the Electronic Air Cleaner (EAC).
IMPORTANT! DO NOT use WASH/CHECK indicators as the
signal to perform routine cleaning. To maintain peak
performance, the EAC cell must be cleaned DAILY as
described in
Section 7.1.8
.
Should
NO
LED indicators turn
ON
when the power is turned
ON
, the EAC system may have a possible internal fault.
A qualified service technician will be required to troubleshoot the problem.
2
If all (3) LED’s are ON at power-up, the EAC cell is not
installed, is misaligned, has a poor connection, or other
problems exist. After (2) minutes, the EAC system will go
into an alarm condition.
3
1. Ensure the airflow indicator arrow points
UP
.
2. Align Cell in the guide Channels and slide into the
chamber. If installed properly, Cell will be flush
with Hood front. If not, alignment pin is not
engaged; Cell is not installed correctly.
3. Replace Access Cover and latch.
Содержание GEF-400
Страница 2: ......
Страница 7: ...vi ...
Страница 27: ...GEF GEF VH Series Fryers Overview 16 Ventless Hood VH Models Only 8 9 7 6 5 4 3 2 1 10 11 12 3 1 Control Panel ...
Страница 35: ...24 GEF GEF VH Series Fryers Overview 3 5 Ventless Hood VH Model Only 2 3 8 6 5 7 4 1 ...
Страница 41: ...30 GEF GEF VH Series Fryers Overview Notes ...
Страница 79: ...68 GEF GEF VH Series Fryers Cleaning ...
Страница 101: ...90 GEF GEF VH Series Fryers Parts List 9 4 Fry Pot 1 2 3 4 5 6 7 7 8 8 9 10 10 10 10 11 Not shown 11 11 11 ...
Страница 109: ...98 GEF GEF VH Series Fryers Parts List 9 8 Front Ventless Hood GEF VH Only 4 6 Not shown 5 2 3 8 7 1 ...
Страница 113: ...102 GEF GEF VH Series Fryers Parts List Notes ...
Страница 114: ......