Problem
Probable Cause
Corrective Action
OIL NOT PUMPING BACK TO FRY
POT:
A. Selector Switch not in
[FILTER
PUMP]
position
Place Switch in proper position
B. Air leak in the system (hoses,
fittings, connector, Filter Pan)
Check & eliminate air leak, be sure
quick-disconnect is secure
C. Pump motor faulty
Check/replace Motor
D. Oil Pump clogged, or damaged
Check/repair Pump
E. Excessive sludge in Filter Pan
Clean Filter Pan, replace media
OIL PUMP LOCKED UP
A. Boil-out solution has been run
through Filter Pump
Disassemble Pump head, clean & re-oil
B. Oil allowed to sit in Pump too long Disassemble Pump head & clean
8.3
Basket Lift System
Problem
Probable Cause
Corrective Action
BASKET LIFT DOES NOT FUNCTION:
A. Power not
ON
Place Power Switch in
ON
position
B. Controller faulty
Check/replace Controller
C. Cooking cycle is running
Cancel cycle or wait for completion
D. Basket Lift micro-switch out of
adjustment
Check/adjust switch
E. Basket Lift micro-switch faulty
Check/replace switch
F. Basket Lift motor/gearbox faulty
Check/replace Lift motor
G. Controller still in
PREHEAT
, oil not
at
READY
temperature.
Allow oil to reach cooking
temperature
Содержание GEF-400
Страница 2: ......
Страница 7: ...vi ...
Страница 27: ...GEF GEF VH Series Fryers Overview 16 Ventless Hood VH Models Only 8 9 7 6 5 4 3 2 1 10 11 12 3 1 Control Panel ...
Страница 35: ...24 GEF GEF VH Series Fryers Overview 3 5 Ventless Hood VH Model Only 2 3 8 6 5 7 4 1 ...
Страница 41: ...30 GEF GEF VH Series Fryers Overview Notes ...
Страница 79: ...68 GEF GEF VH Series Fryers Cleaning ...
Страница 101: ...90 GEF GEF VH Series Fryers Parts List 9 4 Fry Pot 1 2 3 4 5 6 7 7 8 8 9 10 10 10 10 11 Not shown 11 11 11 ...
Страница 109: ...98 GEF GEF VH Series Fryers Parts List 9 8 Front Ventless Hood GEF VH Only 4 6 Not shown 5 2 3 8 7 1 ...
Страница 113: ...102 GEF GEF VH Series Fryers Parts List Notes ...
Страница 114: ......