51
GEF & GEF-VH Series Fryers
Fryer Operation
5.1.10
Controller Errors & Alarms - continued
ERROR CODE DESCRIPTION (OLED Display)
PROBLEM
ER25
GUARD BAND EXCEEDED
Actual oil temperature deviates from setpoint by the Guard
Band amount. Allow oil to cool, or heat, to within range.
Factory default is 900
°
F ...
Error should not occur
.
ER37
EEPROM Error
An error occurred while saving settings to the EEPROM.
Contact
Giles Tech Service (800.554.4537).
ER38
Internal ADC Error
The ADC (Analog-to-Digital Converter) chip that reads output
from thermocouples is not working. MCB1 board must be
replaced.
Contact Giles Tech Service (800.554.4537).
5.1.10.1 Resolving Controller Errors & Alarms
●
DRAIN OPEN (Error Code OPEN) -
If the pot Drain Valve is open (even slightly) while Fryer power is
ON,
an
alarm tone sounds,
Lower 7-Segment Display
shows
“OPEn”
,
and the
Upper OLED Display
reads
“ERROR
ALARM - DRAIN IS OPEN”
.
If the Basket Lift is down, it will be raised. Heating Elements are disabled as long as
the condition exists.
Press the
[ALARM]
key to silence alarm tone. Completely close the Drain Valve to clear the error. When error
is cleared, alarm tone sounds again and the
Upper OLED Display
reads
“CHECK OIL LEVEL, ENSURE VAT IS FULL,
IF FULL THEN PRESS [START]”
.
This is a post-error alarm to alert User to confirm that cooking oil in the pot is
still at the
[FULL]
level. Add oil if needed, then press the
[START]
key to return to
PREHEAT
mode.
●
LOW OIL LEVEL (Error Code 03) -
Alarm tone sounds,
Lower 7-Segment Display
shows
“Er03”
,
and the
Upper
OLED Display
reads
“ERROR ALARM - CHECK OIL LEVEL - ENSURE VAT IS FULL”
.
Heating Elements are disabled
until the condition is corrected. The temperature differential between probe located at the oil level
[ADD]
mark and a probe attached to the heating element exceeds the acceptable value, indicating a low oil level.
Low
oil level greatly increases the possibility of fire!
Press the
[ALARM]
key to silence alarm tone, and place
Selector Switch in
[OFF]
position. Allow the Fryer to adequately cool and then add oil to raise level to the
[FULL]
mark.
●
LOW OIL LEVEL Post-error Warning (Error Code 06)
- After
Error 03
clears, a warning alarm occurs. The
Lower
Display
shows
“
Er06”
,
and the
Upper Display
reads
“CHECK OIL LEVEL - ENSURE VAT IS FULL - PRESS [START]”
.
This alarm alerts user to confirm that cooking oil in the pot is at the
[FULL]
level. If no oil is required press
[START]
, otherwise press
[ALARM]
key to silence tone, add oil, then press
[START]
key to enter
PREHEAT
mode.
●
MAX. ELEMENT TEMP (Error Code 19) -
Heating Element has exceeded the maximum temperature allowed by
the Controller. The alarm tone sounds,
Lower Display
shows
“Er19”
,
and the
Upper Display
shows
“ERROR
ALARM - MAX ELEMENT TEMPERATURE”
.
Heating Element is automatically turned
OFF.
It must cool to an
acceptable temperature to clear the error. Typical cause of this error is low oil level, which has exposed the
heating element. It is possible for a false alarm to occur when preheating cold oil at the initial startup of a new
day. Vigorously stirring oil during preheat will usually prevent, or clear, a false alarm of this type.
Continued on Next Page
Содержание GEF-400
Страница 2: ......
Страница 7: ...vi ...
Страница 27: ...GEF GEF VH Series Fryers Overview 16 Ventless Hood VH Models Only 8 9 7 6 5 4 3 2 1 10 11 12 3 1 Control Panel ...
Страница 35: ...24 GEF GEF VH Series Fryers Overview 3 5 Ventless Hood VH Model Only 2 3 8 6 5 7 4 1 ...
Страница 41: ...30 GEF GEF VH Series Fryers Overview Notes ...
Страница 79: ...68 GEF GEF VH Series Fryers Cleaning ...
Страница 101: ...90 GEF GEF VH Series Fryers Parts List 9 4 Fry Pot 1 2 3 4 5 6 7 7 8 8 9 10 10 10 10 11 Not shown 11 11 11 ...
Страница 109: ...98 GEF GEF VH Series Fryers Parts List 9 8 Front Ventless Hood GEF VH Only 4 6 Not shown 5 2 3 8 7 1 ...
Страница 113: ...102 GEF GEF VH Series Fryers Parts List Notes ...
Страница 114: ......