Field
Description
Possible values:
•
(default value): The system attempts to contact the
time server after 1, 2, 4, 8, and 16 minutes.
•
!!4
: For ten minutes, the system attempts to con-
tact the time server after 1, 2, 4, 8 seconds and then every
10 seconds.
•
"!!
: For an unlimited period, the system attempts to
contact the time server after 1, 2, 4, 8 seconds and then
every 10 seconds.
If certificates are used to encrypt data traffic in a VPN, it is ex-
tremely important that the correct time is set on the device. To
ensure this is the case, for Time Update Policy, select the
value
"!!
.
Internal Time Server
Select whether the internal timeserver is to be used.
The function is activated by selecting
"
. Time requests
from a client will be answered with the current system time.
This is given as GMT, without offset.
The function is enabled by default. Clients' time requests are
answered in the LAN.
2.2.4 Timer
In the Timer menu you can configure the times at which particular system features are to
be switched on by default.
The menu System Management->Global Settings->Timer consists of the following
fields:
Fields in the Basic Settings menu
Field
Description
Call Forwarding
(CFNR)
Enter the time after which a Call Forwarding (CFNR) will be
executed.
Possible values are
to
BB
.
The default value is
.
2 System Management
Gigaset Communications GmbH
16
hybird 120 Gigaset Edition