2-20
UAS 7001 NIU
GDC 087R706-000-02
In response, the screen prompts for confirmation (in the actual displayed message, xxx is
the name of the requested reset):
*WARNING - xxx DISRUPTS COMMUNICATIONS Continue? [ ] Y(es), N(o)
2.
To continue the reset process, type Y and press the Enter key.
In response, the Maintenance screen is replaced by the following message (with the NIU
slot number):
Error: Slot x is not responding. (Press enter)
3.
Press the Enter key.
In response the screen displays the Shelf Inventory. For a Soft Reset the procedure is
complete at this point, and the unit resumes operation with its existing configuration.
The configuration that results from a Reset to Factory Defaults does not enable the unit to
pass data. You must access the Unit Configuration and System Configuration screens to set
up an operating configuration.
Performance
The Performance menu screen shown in Figure 2-12 appears when you type 5 to invoke the
Performance function from the Main Menu. It contains the following selections:
•
ANSI Performance Report (FDL Mode in Unit Configuration must be set to ANSI)
•
TR-54016 Current & Total Error Accumulations
•
TR-54016 Interval Table
To access a Performance display, type the selection number that corresponds to it and press the
Enter key. The following pages describe the individual Performance displays in detail.
Figure 2-12
Performance Menu
UAS 7001 Performance
[1] ANSI Performance Report
[2] TR-54016 Current & Total Error Accumulations
[3] TR-54016 Interval Table
[0] Return to Main Menu
Select: [ ]