UAS 7001 NIU
2-7
GDC 087R706-000-02
Alarm Configuration
Selection 2, Alarm Configuration, from the UAS 7001 Configuration menu calls up the UAS
7001 Alarm Configuration Submenu shown in Figure 2-4. From that submenu you can select the
two screens in which you perform the actual alarm configuration: the Alarm Masks Submenu,
selection 1, or the Performance Alarm Thresholds Submenu, selection 2.
Figure 2-4
Alarm Configuration Screen
The Alarm Masks Configuration Submenu, Figure 2-5, enables you to designate which alarms
are to be reported by means of SNMP traps when they occur and which are to be masked (not
reported). Masking applies only to the SNMP alarm reporting function and the front panel Alarm
(ALM) indicator. The terminal interface Monitor/Alarms function always displays the actual
status of alarm conditions. Some alarm conditions have individual front panel indicators, and the
states of those indicators always accurately reflect the conditions.
The Performance Alarm Thresholds Submenu, Figure 2-6, contains the selections for setting a
Time Interval and Count Threshold for each performance alarm.
The alarm configuration procedure appears following the figures.
UAS 7001 Alarm Configuration Submenu
[1] Alarm Masks Submenu
[2] Performance Alarm Thresholds Submenu
[CR]Return to Previous Menu
[0] Return to Main Menu
Select: [ ]