UAS 7001 NIU
2-9
GDC 087R706-000-02
Figure 2-6
Performance Alarm Thresholds Configuration Screen
The alarm configuration procedure involves the following steps:
1.
From the Alarm Configuration Submenu screen, select 1 and press the Enter key. In re-
sponse the Alarm Masks Configuration Submenu screen is displayed.
You may want to begin by using the [12] All Alarms Control command to set all alarms
Reported or all alarms Masked, depending on how you intend to set the majority of the
alarm options. If you intend to change only selected items, go to step 4.
2.
To use All Alarms Control, type 12 and press the Enter key. In response, highlighting ap-
pears on the All Alarms Control current setting field. Before it’s highlighted the field can
display one of three values: Masked, Reported, or Mixed. Masked and Reported are the val-
ues to which you can set the field; Mixed is a display-only setting that the unit itself writes
to the field when it is appropriate. If Mixed is displayed before you select the option, it
changes to Masked when the highlighting appears.
3.
Use the arrow keys to toggle between the two potential settings, Masked and Reported, and
press the Enter key when the field displays your selected setting. The current setting fields
for all the individual alarms change to match your selection.
The actual change from Mixed to Masked does not occur if you don’t toggle the setting.
Go to step 9 if you don’t need to change any of the individual alarm options. If you do need
to change individual options, follow steps 4 through 8.
4.
Type the selection number of the option you intend to change and press the Enter key.
Highlighting appears on the current setting field for the corresponding option.
5.
Use the arrow keys to toggle the highlighted field through its two potential settings, Masked
and Reported.
UAS 7001 Performance Alarms Thresholds Submenu
Type Time Interval Count Threshold
Bipolar Violations : [1] Not Used [7] 10,000
CRC Errors : [2] Not Used [8] 10,000
Errored Seconds : [3] Not Used [9] 10,000
Severely Errored Seconds : [4] Not Used [10] 10,000
Bursty Errored Seconds : [5] Not Used [11] 10,000
Unavailable Seconds : [6] Not Used [12] 10,000
[CR]Return to Previous Menu [S] Save
[0] Return to Main Menu
Select: [ ]