UAS 7616 DIU
4-17
GDC 087R706-000-02
Table 4-3
Diagnostic
Option Settings
The Diagnostic procedure involves the following steps:
1.
From the Main Menu, select the Diagnostics screen by typing
2
and pressing the Enter key.
2.
To select a test to be performed, type the appropriate selection number and press the Enter
key. Highlighting appears on the current setting field.
3.
Use the arrow keys to toggle the highlighted field from
Idle
to
Active
.
4.
When the field displays
Active
, press the Enter key. The highlighting disappears and the
field displays the new setting.
5.
To start the test, type S (Save) and press the Enter key.
In response, the screen prompts for confirmation:
*WARNING - SAVING DISRUPTS COMMUNICATIONS Continue? [ ] Y(es), N(o)
6.
To perform the test type
Y
and press the Enter key; to abort the test type
N
and press the
Enter key.
If you continue, the word
SAVING
appears at the bottom of the screen. When it disappears
the test is in effect. It continues until you end it manually.
If you are performing a Self Test, the words
No Errors Detected
appear in the Self Test
Results field when the test begins. If errors occur during the test, the display changes to
Errors Detected!!!
7.
To end a test: type its selection number and press the Enter key; toggle the highlighted field
to
Idle
and press the Enter key; save the setting as described in steps 5 and 6.
8.
When you’re done with the Diagnostics screen, type
0
and press the Enter key to return to
the Main Menu.
Option
Potential Settings
[0] Return to Main Menu
Returns you to the UAS 7616 Main Menu.
LOOPn TESTS
(Three groups, one for each loop)
[x] Digital Loop Channel _:
Idle
Active – commands digital loopback toward network
[x] Self Test Channel _:
Idle
Active – commands loopback toward DTE with Self Test and error check
[x] Remote Digital Loop Channel _:
Idle
(UAS 7616ML only)
Active – commands digital loopback at the remote toward network and 7616
[S] Save