2-22
UAS 7001 NIU
GDC 087R706-000-02
When you’re done viewing the Performance Report Submenu, you may either return to the
Performance Menu screen by pressing the Enter key – identified as
CR
(Carriage Return) in the
screen prompt – or return to the Main Menu by typing
0
and pressing the Enter key.
TR-54016 Current & Total Errors
When you select TR-54016 Current & Total Error Accumulations, the screen displays the UAS
7001 TR-54016 Current & Totals Submenu screen shown in Figure 2-14. The screen displays
information on five error conditions that can occur in the unit:
Errored Seconds (ES)
Severely Errored Seconds (SES)
Bursty Errored Seconds (BES)
Unavailable Seconds (UAS)
Loss of Frame Count (LOFC)
The line labeled Current displays counts for the current, incomplete, fifteen-minute interval.
The line labeled Total displays the accumulated total counts for up to 24 hours. When the
accumulation of data is permitted to continue without interruption, the unit stores 96 15-minute
intervals of TR-54016 data. It drops the oldest interval from its totals as each new interval is
completed. The Maintenance Screen Reset Statistics command begins a new count, with all
intervals set to 0.
When you’re done viewing the TR-54016 Current & Totals Submenu, you may either return to
the Performance Menu screen by pressing the Enter key – identified as
CR
(Carriage Return) in
the screen prompt – or return to the Main Menu by typing
0
and pressing the Enter key.
Figure 2-14
UAS 7001 TR-54016 Current & Totals Screen
UAS 7001 TR-54016 Current & Totals Submenu
ES SES BES UAS LOFC
CURRENT 0 0 0 622 0
TOTALS 0 0 0 64800 0
[CR] Return to Previous Menu
[0] Return to Main Menu
Select: [ ]