![Geehy SEMICONDUCTOR APM32F405 Series Скачать руководство пользователя страница 281](http://html1.mh-extra.com/html/geehy-semiconductor/apm32f405-series/apm32f405-series_user-manual_573630281.webp)
www.geehy.com Page 280
Register functional description
RTC time register (RTC_TIME)
RTC_TIME is time shadow register, and this register can be written only in
initialization mode to be put in write protection state.
Offset address: 0x00
Reset value of backup domain: 0x0000 0000
System reset: RCMCFG =0: 0x0000 0000; RCMCFG =1: 0xXXXX XXXX
Field
Name
R/W
Description
3:0
SECU
R/W Second Ones Unit in BCD Format Setup
6:4
SECT
R/W Second Ten's Place Unit in BCD Format Setup)
7
Reserved
11:8
MINU
R/W Minute Ones Unit in BCD Format Setup
14:12
MINT
R/W Minute Ten's Place Unit in BCD Format Setup
15
Reserved
19:16
HRU
R/W Hour Ones Unit in BCD Format Setup
21:20
HRT
R/W Hour Ten's Place Unit in BCD Format Setup
22
TIMEFCFG R/W
Time Format Configure
0: AM or 24-hour system
1: PM
31:23
Reserved
RTC date regiter (RTC_DATE)
RTC_DATE is date shadow register, and this register can be written only in
initialization mode to be put in write protection state.
Offset address: 0x04
Reset value of backup domain: 0x0000 2101
System reset: RCMCFG =0: 0x0000 0000; RCMCFG =1: 0xXXXX XXXX
Field
Name
R/W
Description
3:0
DAYU
R/W Day Ones Unit in BCD Format Setup
5:4
DAYT
R/W Day Ten's Place Unit in BCD Format Setup
7:6
Reserved
11:8
MONU
R/W Month Ones Unit in BCD Format Setup
12
MONT
R/W Month Ten's Place Unit in BCD Format Setup
15:13 WEEKSEL R/W
Week Day Units Select
000: Disable
001: Monday
...
111: Sunday