CHAPTER 3: IEC 61850 COMMUNICATION
MODEL IMPLEMENTATION CONFORMANCE STATEMENT (MICS)
UR SERIES – COMMUNICATIONS GUIDE
3-79
3
Table 3-80: Fault report settings data objects
cVal.ang.f
FLOAT32
0
R
RsStat
SPC
Instantiated only in FltRptRFLO1
R/Ctrl
pulseConfig
PulseConfig
CF
R
pulseConfig
.cmdQual
ENUMERATED
0 (pulse)
R
pulseConfig.onDur INT32U
2 ms (actually one pass)
R
pulseConfig
.offDur
INT32U
0
R
pulseConfig
.numPls
INT32U
1
R
ctlModel
CtlModels
CF FltRptRFLO1.RsStat.ctlModel
R/W/C
sboTimeout
INT32U
CF
30000
R
sboClass
SboClasses
CF
0 (operate-once)
R
operTimeout
INT32U
CF
0
R
InRef1
ORG
FAULT REPORT# TRIG
R
setSrcRef
ObjectReference
SP FAULT REPORT# TRIG.
Reference to the data attribute to input
R/C
setSrcCB
ObjectReference
SP
Source GoCB of input if via GOOSE
R/C
InRef2
ORG
Only instantiated in FltRptRFLO1
R
setSrcRef
ObjectReference
SP CLEAR FAULT REPORTS
Reference to the data attribute to input
R/C
setSrcCB
ObjectReference
SP
Source GoCB of input if via GOOSE
R/C
LNName:
FltRFLO
ψψ
LDevice inst:
Gen
UR element:
Selected values from Fault Report Data file
ψψ
data obj. data attribute
Type
FC UR Name
Description
R/W/C
FltZ
CMV
Mandatory data attribute which in this case
is fixed at zero
R
cVal
Vector
MX
R
cVal.mag.f
FLOAT32
Fault impedance magnitude in
primary ohms calculated as
shown below
R
cVal.ang.f
FLOAT32
Fault impedance angle in degrees
calculated as shown below
R
FltNum
INS
FAULT NUMBER
R
stVal
INT32
ST FAULT NUMBER in Fault Report
Data file
ψψ
R
units
UNIT
CF
R
units.SIUnit
ENUMERATED
1, the code for dimensionless
R
units.multiplier
ENUMERATED
0, the code for a multiplier of 1
R
FltLinID
VSS
Faulted line ID
R
stVal
VISIBLE STRING
255
ST LINE ID in Fault Report Data file
ψψ
R
FltLoop
ENS
FAULT TYPE
R
stVal
ENUMERATED
ST FAULT TYPE in Fault Report Data
file
ψψ
R
FltDiskm
MV
FAULT LOCATION
R
mag
Analogue Value
MX
R
mag.f
FLOAT32
FAULT LOCATION in Fault Report
Data file
ψψ
, converted to
kilometers where required
R
units
Unit
CF
R
units.SIUnit
ENUMERATED
2, the code for meter
R
units.multiplier
ENUMERATED
3, the code for a multiplier of 1000
R
RecCyc
INS
FAULT RECLOSE SHOT
R
LNName:
FltRptRFLO#
LDevice inst:
Gen
UR element:
FAULT REPORT # settings
data obj. data attribute
Type
FC UR Name
Description
R/W/C
Содержание UR series
Страница 5: ...TABLE OF CONTENTS UR SERIES COMMUNICATIONS GUIDE v INDEX...
Страница 6: ...vi UR SERIES COMMUNICATIONS GUIDE TABLE OF CONTENTS...
Страница 20: ...1 14 UR SERIES COMMUNICATIONS GUIDE FOR FURTHER ASSISTANCE CHAPTER 1 INTRODUCTION 1...
Страница 216: ...2 196 UR SERIES COMMUNICATIONS GUIDE MEMORY MAP CHAPTER 2 MODBUS COMMUNICATION 2...
Страница 428: ...A 2 UR SERIES COMMUNICATIONS GUIDE REVISION HISTORY APPENDIX A MISCELLANEOUS A...