O P E R A T I N G I N S T R U C T I O N S
ReLy OSSD3
Safety relay
Страница 1: ...O P E R A T I N G I N S T R U C T I O N S ReLy OSSD3 Safety relay...
Страница 2: ...sible within the limits of the legal determination of Copyright Law Any modifica tion abridgment or translation of this document is prohibited without the express writ ten permission of SICK AG The tr...
Страница 3: ...erlock 10 3 2 5 External device monitoring 10 3 2 6 Status indicators 10 4 Project planning 11 4 1 Manufacturer of the machine 11 4 2 Operating entity of the machine 11 4 3 Design 11 4 4 Electrical in...
Страница 4: ...al data 24 10 1 Data sheet 24 10 2 Dimensional drawings 28 10 3 Internal circuitry 29 11 Ordering information 30 11 1 Ordering information for ReLy 30 12 Annex 31 12 1 Compliance with EU directives 31...
Страница 5: ...manufacturer and the entity operating the machine in which the device is to be integrated Area of responsibility Target group Specific chapters of these operating instruc tions 1 Manufacturer Project...
Страница 6: ...er which may lead to moderate or minor injuries if not prevented NOTICE Indicates a situation presenting possible danger which may lead to property damage if not prevented NOTE Indicates useful tips a...
Страница 7: ...ntentionally generated and or used conductor bound RF energy that is required for the inner function of the device itself occurs The safety relay must only be used within the limits of the prescribed...
Страница 8: ...sk a person is considered qualified when he she has the expertise and expe rience in the relevant field and is sufficiently familiar with the application of the protec tive device on the machine to be...
Страница 9: ...another Actuators with positively guided contacts are connected to the enabling current paths 3 2 Product characteristics 3 2 1 Device overview RELY PWR OUT 13 23 I1 Y1 14 24 I2 Y2 A2 S1 33 A1 R1 34...
Страница 10: ...1 Y1 14 24 I2 Y2 A2 R1 A1 S1 OSSD3 1099969 RELY 33 34 Figure 2 LEDs The labeled positions are only partially assigned LEDs The positions and their labeling except for the upper 2 lines also show the p...
Страница 11: ...risk assessment may require the entity operating the machine to meet the obligations of a manufac turer b Apart from the procedures described in this document the components of the safety relay must...
Страница 12: ...nected via safety sen sors or safety switches in order to switch the enabling current paths 4 4 1 Enabling current paths DANGER Hazard due to lack of effectiveness of the protective device b Ensure th...
Страница 13: ...rlock A reset pushbutton must be connected to allow the restart interlock to be used The reset pushbutton must be attached outside of the hazardous area It must not be possi ble to access the reset pu...
Страница 14: ...t of modifications or other influences e g damage or manip ulation The manufacturer and user must define the type and frequency of the thorough checks on the machine on the basis of the application co...
Страница 15: ...is done in accordance with EN 50274 and electrical installation in accordance with IEC 60204 1 in the control cabinet with enclosure rating IP54 Mounting must be done on a non flammable base Mounting...
Страница 16: ...mounting rail 5 4 Module exchange Approach 1 Disconnect module and the connected components from all voltage sources 2 Take front connector with connected cables off the defective device Press the un...
Страница 17: ...the new module First mount in the module with bent hook and then engage in the housing Click Figure 8 Mount the front connector The front connector engages with an audible click MOUNTING 5 8023925 201...
Страница 18: ...Electrical installation is done in conformity with IEC 60204 1 The mounting rail is connected to the functional earth The voltage supply and connected signals meet the requirements for safety extra lo...
Страница 19: ...el base device Connect jumper between I1 and I2 4 Use with restart interlock with external device monitoring EDM Connect the N C contacts of the actuators between voltage supply Uv the N O contact of...
Страница 20: ...Further topics Connection diagrams page 14 6 ELECTRICAL INSTALLATION 20 O P E R A T I N G I N S T R U C T I O N S ReLy OSSD3 8023925 2019 10 11 SICK Subject to change without notice...
Страница 21: ...mounting or the electrical installation After exceptional events such as after manipulation has been detected after modification of the machine or after replacing components The thorough check ensure...
Страница 22: ...y voltage All LEDs All colors Initialization with LED test PWR O Green No fault PWR Red Supply voltage too low temporarily or per manently Internal error PWR Red green Error Additional LEDs flash for...
Страница 23: ...in accordance with national waste disposal regulations Complementary information SICK will be glad to help you dispose of these devices on request DECOMMISSIONING 9 8023925 2019 10 11 SICK O P E R A T...
Страница 24: ...erous failure on demand 2 For operating heights 2 000 m above sea level 5 10 5 5 10 4 5 10 3 For operating heights 2 000 4 000 m above sea level 2 5 10 4 2 5 10 3 5 10 3 TM mission time 20 years ISO 1...
Страница 25: ...olt age supply UV must be protected with 4 A Table 8 Electrical data inputs I1 I2 S1 Input voltage HIGH 24 V DC 11 V DC 30 V DC Input voltage LOW 0 V DC 3 V DC 5 V DC Input capacity 15 nF Input curren...
Страница 26: ...60947 5 1 DC switching capacity 0 1 W 200 W see figure 10 page 27 AC switching capacity 0 1 VA 1 500 VA Switching frequency 1 Hz Mechanical service life 10 106 switching operations Contact fuse with s...
Страница 27: ...condensing for climatic con ditions according to IEC 61131 2 Emitted interference In accordance with IEC 61000 6 4 Immunity to interference In accordance with IEC 61326 3 1 In accordance with IEC 610...
Страница 28: ...al service life 1 Switching operations 1 000 2 Switching current A 10 2 Dimensional drawings 20 1 18 85 5 87 7 124 6 64 4 128 3 78 7 120 7 Figure 12 Dimensional drawing 10 TECHNICAL DATA 28 O P E R A...
Страница 29: ...10 3 Internal circuitry Figure 13 Internal circuitry TECHNICAL DATA 10 8023925 2019 10 11 SICK O P E R A T I N G I N S T R U C T I O N S ReLy OSSD3 29 Subject to change without notice...
Страница 30: ...g information Part Usage Type code Part number ReLy OSSD3 Opto electronic protec tive devices magnetic safety switches RLY3 OSSD3 1099969 11 ORDERING INFORMATION 30 O P E R A T I N G I N S T R U C T I...
Страница 31: ...l specifications stated in the EU declaration of conformity have been used as a basis for this Complete EU declaration of conformity for download You can call up the EU declaration of conformity and t...
Страница 32: ...smantle front connector 16 8 Mount the front connector 17 9 Terminals on front connector 19 10 Switch off delay without continuous arcing 27 11 Electrical service life 28 12 Dimensional drawing 28 13...
Страница 33: ...anical data 24 7 Electrical data operating data 25 8 Electrical data inputs I1 I2 S1 25 9 Electrical data test pulse output R1 25 10 Electrical data application diagnostic output Y1 Y2 26 11 Electrica...
Страница 34: ...14 LIST OF TABLES 34 O P E R A T I N G I N S T R U C T I O N S ReLy OSSD3 8023925 2019 10 11 SICK Subject to change without notice...
Страница 35: ...LIST OF TABLES 14 8023925 2019 10 11 SICK O P E R A T I N G I N S T R U C T I O N S ReLy OSSD3 35 Subject to change without notice...
Страница 36: ...8080 7425 E Mail enquiry my sick com Mexico Phone 52 472 748 9451 E Mail mexico sick com Netherlands Phone 31 0 30 229 25 44 E Mail info sick nl New Zealand Phone 64 9 415 0459 0800 222 278 tollfree...