2-28
UR SERIES – COMMUNICATIONS GUIDE
MEMORY MAP
CHAPTER 2: MODBUS COMMUNICATION
2
Breaker Arcing Current Actual Values (Read Only Non-Volatile) (2, 4, or 6 Modules)
C60, D30, D60,
F35, F60, L30,
L60, L90, T35,
T60
21E0
Breaker 1 Arcing Current Phase A
0 to 99999999
kA
2
-cyc 1
F060
0
"
21E2
Breaker 1 Arcing Current Phase B
0 to 99999999
kA
2
-cyc 1
F060
0
Bus Actuals (Read Only) (6 Modules)
B90
21E2
...Repeated for Bus Zone 2 - continued
0 to 99999999
kA
2
-cyc 1
F060
0
Breaker Arcing Current Actual Values (Read Only Non-Volatile) (2, 4, or 6 Modules)
C60, D30, D60,
F35, F60, L30,
L60, L90, T35,
T60
21E4
Breaker 1 Arcing Current Phase C
0 to 99999999
kA
2
-cyc 1
F060
0
Bus Actuals (Read Only) (6 Modules)
B90
21E5
...Repeated for Bus Zone 2 - continued
Breaker Arcing Current Actual Values (Read Only Non-Volatile) (2, 4, or 6 Modules)
C60, D30, D60,
F35, F60, L30,
L60, L90, T35,
T60
21E6
Breaker 1 Operating Time Phase A
0 to 65535
ms
1
F001
0
"
21E7
Breaker 1 Operating Time Phase B
0 to 65535
ms
1
F001
0
Bus Actuals (Read Only) (6 Modules)
B90
21E8
...Repeated for Bus Zone 2 - continued
Breaker Arcing Current Actual Values (Read Only Non-Volatile) (2, 4, or 6 Modules)
C60, D30, D60,
F35, F60, L30,
L60, L90, T35,
T60
21E8
Breaker 1 Operating Time Phase C
0 to 65535
ms
1
F001
0
"
21E9
Breaker 1 Operating Time
0 to 65535
ms
1
F001
0
"
21EA
...Repeated for Breaker 2
Bus Actuals (Read Only) (6 Modules)
B90
21EC
...Repeated for Bus Zone 3
Breaker Arcing Current Actual Values (Read Only Non-Volatile) (2, 4, or 6 Modules)
C60, D30, D60,
F35, F60, L30,
L60, L90, T35,
T60
21EE
...Repeated for Breaker 2
Bus Actuals (Read Only) (6 Modules)
B90
21F0
...Repeated for Bus Zone 3 - continued
Breaker Arcing Current Actual Values (Read Only Non-Volatile) (2, 4, or 6 Modules)
C60, D30, D60,
F35, F60, L30,
L60, L90, T35,
T60
21F0
...Repeated for Breaker 2
Bus Actuals (Read Only) (6 Modules)
B90
21F1
...Repeated for Bus Zone 3 - continued
Breaker Arcing Current Actual Values (Read Only Non-Volatile) (2, 4, or 6 Modules)
C60, D30, D60,
F35, F60, L30,
L60, L90, T35,
T60
21F2
...Repeated for Breaker 2
Bus Actuals (Read Only) (6 Modules)
B90
21F3
...Repeated for Bus Zone 3 - continued
"
21FA
...Repeated for Bus Zone 4
Products
Address Register name
Range
Units
Step
Format
Default
Содержание UR series
Страница 5: ...TABLE OF CONTENTS UR SERIES COMMUNICATIONS GUIDE v INDEX...
Страница 6: ...vi UR SERIES COMMUNICATIONS GUIDE TABLE OF CONTENTS...
Страница 20: ...1 14 UR SERIES COMMUNICATIONS GUIDE FOR FURTHER ASSISTANCE CHAPTER 1 INTRODUCTION 1...
Страница 216: ...2 196 UR SERIES COMMUNICATIONS GUIDE MEMORY MAP CHAPTER 2 MODBUS COMMUNICATION 2...
Страница 428: ...A 2 UR SERIES COMMUNICATIONS GUIDE REVISION HISTORY APPENDIX A MISCELLANEOUS A...