3.5.2.43 Restricted ground fault (RgDif)
This element is instantiated in the following products: F60, G30, G60, L90, T60.
Table 3-64: Restricted ground fault data objects
stVal
BOOLEAN
ST POWER SWING OUTER
R
Z1Chr2
SPS
POWER SWING MIDDLE operand
R
stVal
BOOLEAN
ST POWER SWING MIDDLE
R
Z1Chr3
SPS
POWER SWING INNER operand
R
stVal
BOOLEAN
ST POWER SWING INNER
R
TmStr2
SPS
POWER SWING TMR2 PKP operand
R
stVal
BOOLEAN
ST POWER SWING TMR2 PKP
R
TmStr3
SPS
POWER SWING TMR3 PKP operand
R
stVal
BOOLEAN
ST POWER SWING TMR3 PKP
R
TmStr4
SPS
POWER SWING TMR4 PKP operand
R
stVal
BOOLEAN
ST POWER SWING TMR4 PKP
R
Blk
SPS
POWER SWING UN/BLOCK operand
R
stVal
BOOLEAN
ST POWER SWING UN/BLOCK
R
DistDet
SPS
POWER SWING 50DD operand
R
stVal
BOOLEAN
ST POWER SWING 50DD
R
InRef
γ
2
ORG
POWER SW I2 SUPV ENAB setting for setting
group
γ
R
setSrcRef
ObjectReference
SP POWER SW I2 SUPV ENAB setting Reference to the data attribute to input
R/C
setSrcCB
ObjectReference
SP
Source GoCB of input if via GOOSE
R/C
BlkRef
γ
ORG
POWER SWING BLK setting for setting
group
γ
R
setSrcRef
ObjectReference
SP POWER SWING BLK
Reference to the data attribute to input
R/C
setSrcCB
ObjectReference
SP
Source GoCB of input if via GOOSE
R/C
LNName:
RgDifPDIF#
LDevice inst:
Prot
UR element:
Restricted Ground Fault # function
data obj. data attribute
Type
FC UR Name
Description
R/W/C
Op
ACT
RESTD GND FT# OP operands
R
general
BOOLEAN
ST RESTD GND FT# OP
R
Dpo
SPS
RESTD GND FT# DPO operand
R
stVal
BOOLEAN
ST RESTD GND FT# DPO
R
Str
ACD
RESTD GND FT# PKP operand
R
general
BOOLEAN
ST RESTD GND FT# PKP
R
dirGeneral
ENUMERATED
ST
1 is code for Forward
R
DifAClc
WYE
Differential currents
R
net
CMV
R
net.instCVal
Vector
MX
R
net.instCVal.mag
.f
FLOAT32
RGF# DIFF Igd magnitude, in
primary amps
R
net.cVal
Vector
MX
R
net.cVal.mag.f
FLOAT32
RGF# DIFF Igd magnitude, in
primary amps, with deadband
R
net.units
Unit
CF
R
net.units.SIUnit
ENUMERATED
5, the code for amps
R
net.units
.multiplier
ENUMERATED
0, the code for a multiplier of 1
R
net.db
INT32U
CF RgDifPDIF#.DifAClc.net.db
R/W/C
net.zeroDb
INT32U
CF
R
LNName:
PwrSwgRPSB1
LDevice inst:
Prot
UR element:
Power Swing Detect element
data obj. data attribute
Type
FC UR Name
Description
R/W/C
Содержание UR series
Страница 5: ...TABLE OF CONTENTS UR SERIES COMMUNICATIONS GUIDE v INDEX...
Страница 6: ...vi UR SERIES COMMUNICATIONS GUIDE TABLE OF CONTENTS...
Страница 20: ...1 14 UR SERIES COMMUNICATIONS GUIDE FOR FURTHER ASSISTANCE CHAPTER 1 INTRODUCTION 1...
Страница 216: ...2 196 UR SERIES COMMUNICATIONS GUIDE MEMORY MAP CHAPTER 2 MODBUS COMMUNICATION 2...
Страница 428: ...A 2 UR SERIES COMMUNICATIONS GUIDE REVISION HISTORY APPENDIX A MISCELLANEOUS A...