6-9. Alarms
6-9-1. Alarm Settings
The ALARM / LOSS / SENSOR menu sets several parameters related to alarm inputs, resets
and indications when alarms occur. See sec. ‘5-1. Accessing MAIN Menu’ for information on
making menu selections.
Where:
①
ALARM INPUT
Sets the type of alarm input accepted by the CDR-16T from external alarm devices.
LEVEL
Alarm response initiated by signal level change. LOW level signal creates
alarm condition. Alarm automatically reset when signal level returns to
HIGH.
TRIG
Alarm response triggered by pulse input. LOW level pulse (signal) initiates
alarm condition. Setting at
⑥
below resets alarm.
②
SENSOR INPUT
Sets the type of alarm input accepted by the CDR-16T.
LEVEL
Sensor alarm response initiated by signal level change. LOW level signal
creates alarm condition. Alarm automatically reset when signal level
returns to HIGH.
TRIG
Sensor alarm response triggered by pulse input. LOW level pulse (signal)
initiates alarm condition. Setting at
⑧
below resets alarm.
①
②
③
④
⑤
⑥
⑦
⑧
[ALARM / LOSS / SENSOR]
ALARM INPUT – LEVEL
SENSOR INPUT – LEVEL
ALARM DISPLAY – FULL
ALM – ON
LOSS – ON
SENS – ON
BUZZER
ALM – ON
LOSS – ON
SENS – ON
ALARM OUT – ALARM
ALM – ON
LOSS – ON
SENS – ON
ALARM RESET – 00M30S
LOSS RESET – 00M10S
SENSOR RESET – 00M10S
SET
EXIT