TRIGGER
Sets which type of input trigger will initiate PRE ALARM record operation. See sec. ‘6-3-6.
Regarding Trigger Setting’ for details.
OFF
Alarm record operation not initiated.
ALARM
Input via external sensor devices (rear panel alarm input
connector) initiates alarm record operation.
SENSOR
Input via sensor board installed to CDR-16T initiates alarm record
operation.
ALM / SENS
Input via internal sensor board initiates alarm record operation.
u
Example 1: TOTAL ALARM REC = 10M 0S, PRE ALARM REC = 4M 0S
If CH2 goes to alarm status.
u
Example 2: TOTAL ALARM REC = 10M 0S, PRE ALARM REC = 4M 0S
If CH2 goes to alarm status then CH9 goes to alarm status.
Not recording
Record
CH1 – 16
4 min. prior
Record
CH1 – 16
6 min. after
Not recording
10 min. alarm video
CH 2
Alarm input
Pre-alarm
time start
CH 2 alarm
time finish
Alarm video 10 min. + time between alarms if new alarm
occurs
before
total alarm record time is complete.
(10 min. + 3min. between alarms 2 and 9)
Not
recording
Record
CH1 – 16
4 min. prior
Record
CH1 – 16
3 min. after
Record
CH1 – 16
6 min. after
Not
recording
CH 2
Alarm input
Pre-alarm
time start
CH 9 alarm
time finish
CH 9
Alarm input