64
u
SWITCHOVER
If this setting made, and multiple channel alarms occur, all cameras concurrently in alarm will
be switched every field and recorded during the multiple alarm period.
u
ALL CHANNELS
All channels (alarm and normal) sequenced each frame, except SKIP set channels, and
recorded real time during alarm.
Exception:
If alarm occurs at SKIP set channel, that
channel will also be recorded.
u
PRIORITY
Same response as ALL CHANNEL setting (D above),
except
alarm channels go to FAST
update mode, other channels go to NORM update mode.
Important
PRIORITY alarm record cannot be performed if the
number of alarm channels is more than the number of
non-alarm channels, or if more than 7 channels are in
alarm at the same time.
If PRIORITY alarm record cannot be performed, setting
will automatically change to ALL CHANNEL. Setting will
not automatically return to PRIORITY after alarm reset.
u
SEQUENCE
If you are using sensor devices to input alarms, and they are area mounted (not on each
camera), this setting allows you to set which cameras in the sensor covered area are
recorded and for how long. Settings for cameras and record time are made in ALARM SEQ
REC sub menu shown below.
Note
TRIGGER sub menu is invalid when ALARM REC MODE
is set to SEQUENCE.
Record
CH1 - 16
CH1 only
record
CH1 and 2
alternate
record
CH2 only
record
Record
CH1 - 16
CH2
Alarm
input
CH2 Alarm reset
CH1
Alarm
input
Alarm video (realtime)
CH1
Alarm
reset
(Continued following page.)