49
Note
If CONTINUOUS mode is selected, QUALITY setting can
be independently made for alarm record (ALARM
QUALITY) and non-alarm record (QUALITY) operation.
6-3-1. Continuous Record
When you select CONTINUOUS as the REC MODE setting in the RECORD menu, you can
record continuously and automatically change to real time recording (NTSC: 60 fields / sec.,
PAL: 50 fields / sec.) when an alarm is input. Settings displayed in this menu should be
similar to those shown below. See sec. ‘5-1. Accessing MAIN Menu’ for information on
making menu selections.
Important
Settings
①
–
③
are not explained here as they are the
same For all recording modes. Refer to sec. ‘6-3. Record
Programming’ previous.
Where:
④
AUDIO record
OFF
No audio input or no audio record performed.
MONO
Mono audio input and recorded.
STEREO
Stereo audio input and recorded.
⑤
REC CHANNEL
Accesses sub menu that allows user to set update frequency (NORM, FAST or SENS) for
each camera channel or whether the camera channel skipped (not recorded) when record
program is applied. See sec. ‘6-3-4. Regarding Record Channel Setting’.
(Continued following page.)
①
②
③
④
⑤
⑥
⑦
⑧
⑨
⑩
⑪
⑫
[RECORD]
PROGRAM – NO.1
REC MODE – CONTINUOUS
QUALITY – NORMAL
AUDIO – OFF
REC CHANNEL
NORM = 4 FAST = 2 SENS = 0
TIMELAPSE MODE 0.10SEC
UPDATE (NORM, SENS) = 0.80SEC
UPDATE (FAST) = 0.40SEC
TOTAL REC TIME= 30H52M
ALARM REC MODE –
SEQUENCE
ALARM QUALITY – SUPER
TRIGGER
ALARM SEQ REC
SET
EXIT