54
6-3-3. One Shot Record
When you input ONE SHOT as the REC MODE setting in the RECORD menu, settings
displayed in the menu should be as indicated below. See sec. ‘5-1. Accessing MAIN Menu’
for information on making menu selections.
Important
Settings
①
–
③
are not explained here as they are the
same For all recording modes. See sec. ‘6-3. Record
Programming’ previous.
Where:
④
INTERVAL
Sets fixed time interval between ‘take’ of each video capture shot. Selectable 1 – 240 fields.
For example, if you set 50 FIELDS, one frame of video from alarm channel will be captured
every 50 fields.
⑤
TAKES
Sets how many video capture ‘takes’ are performed during an alarm. Selectable as 1 – 20
max. For example, if you set 5 TAKES, five 1 – frame shots will be captured and alarm
recording will end.
(Continued following page.)
①
②
③
④
⑤
⑥
[RECORD]
PROGRAM – NO.1
REC MODE – ONE SHOT
QUALITY – NORMAL
INTERVAL – 5FIELDS
TAKES – 5TAKES
TRIGGER
SET
EXIT