![Fujitsu Siemens Computers PRIMERGY BX Скачать руководство пользователя страница 91](http://html.mh-extra.comprimergy-bx_description_2344753091.png)
Main Menu Web-Based Management Interface
Lan Switch and Router Blade
91
Rx FCS Errors
- The total number of packets received that had a length (excluding
framing bits, but including FCS octets) of between 64 and 1518 octets, inclusive, but had a
bad Frame Check Sequence (FCS) with an integral number of octets
Overruns
- The total number of frames discarded as this port was overloaded with
incoming packets, and could not keep up with the inflow.
Total Packets Transmitted (Octets)
- The total number of octets of data (including those
in bad packets) transmitted on the network (excluding framing bits but including FCS
octets). This object can be used as a reasonable estimate of ethernet utilization. If greater
precision is desired, the etherStatsPkts and etherStatsOctets objects should be sampled
before and after a common interval.
Packets Transmitted 64 Octets
- The total number of packets (including bad packets)
received that were 64 octets in length (excluding framing bits but including FCS octets).
Packets Transmitted 65-127 Octets
- The total number of packets (including bad packets)
received that were between 65 and 127 octets in length inclusive (excluding framing bits
but including FCS octets).
Packets Transmitted 128-255 Octets
- The total number of packets (including bad
packets) received that were between 128 and 255 octets in length inclusive (excluding
framing bits but including FCS octets).
Packets Transmitted 256-511 Octets
- The total number of packets (including bad
packets) received that were between 256 and 511 octets in length inclusive (excluding
framing bits but including FCS octets).
Packets Transmitted 512-1023 Octets
- The total number of packets (including bad
packets) received that were between 512 and 1023 octets in length inclusive (excluding
framing bits but including FCS octets).
Packets Transmitted 1024-1518 Octets
- The total number of packets (including bad
packets) received that were between 1024 and 1518 octets in length inclusive (excluding
framing bits but including FCS octets).
Packets Transmitted 1523-2047 Octets
- The total number of packets (including bad
packets) received that were between 1523 and 2047 octets in length inclusive (excluding
framing bits but including FCS octets).
Packets Transmitted 2048-4095 Octets
- The total number of packets (including bad
packets) received that were between 2048 and 4095 octets in length inclusive (excluding
framing bits but including FCS octets).
Packets Transmitted 4096-9216 Octets
- The total number of packets (including bad
packets) received that were between 4096 and 9216 octets in length inclusive (excluding
framing bits but including FCS octets).
Maximum Frame Size
- The maximum ethernet frame size the interface supports or is
configured, including ethernet header, CRC, and payload. (1518 to 9216). The default
maximum frame size is 1518 .
Содержание PRIMERGY BX
Страница 84: ...Main Menu Web Based Management Interface Lan Switch and Router Blade 84...
Страница 94: ...Main Menu Web Based Management Interface Lan Switch and Router Blade 94...
Страница 115: ...Main Menu Web Based Management Interface Lan Switch and Router Blade 115...
Страница 174: ...Main Menu Web Based Management Interface Lan Switch and Router Blade 174...
Страница 252: ...Main Menu Web Based Management Interface Lan Switch and Router Blade 252...
Страница 284: ...Main Menu Web Based Management Interface Lan Switch and Router Blade 284...