CHAPTER 4 PARAMETER
4-120
Extension Function 2 Setting Parameters
4
Speed
Time
Collision occurrence
Collision
(1)
(2)
(3)
(1)
(2)
(3)
PA4_03: Interference detection return speed
PA4_02: Interference
detection return value
[How to return to regular operation]
If the interference detection function worked to make the motor retract in the direction of no
interference, operation in a regular manner is enabled after this signal is turned off.
In position control mode (pulse operation) and speed control mode, however, the operations in the
following table must be performed to return to the regular operation:
Operation mode
Restoration method
Position control (pulse operation)
Restart the servo amplifier.
Servo ON signal = OFF
Alarm reset signal = ON
Speed control
Restart the servo amplifier.
Servo ON signal = OFF
FWD signal/REV signal = OFF
PA4_10 Enable/disable SEMI F47 compatible function
No.
Name
Setting range
Default
value
Change
10
Enable/disable SEMI F47
compatible function
0: Disable, 1: Enable
0
Power
supply
This setting ensures compatibility with the SEMI F47 standard.
By setting this parameter to “1: Enable”, the control power undervoltage alarm level and main power
shutoff detection time will be changed, allowing operation stoppages due to alarms to be circumvented,
and operation to be continued.
•
The main power supply is a three-phase power supply, and is compatible with no loads and light
loads. This parameter is not applicable for use with single-phase power supplies.
•
When set to "1: Enable", the settings of PA2_68 (Main power shutoff detection time) are disabled.
•
Be sure to carry out a detailed check for the SEMI F47 standard on the actual customer
’
s equipment.
Содержание ALPHA7
Страница 1: ......
Страница 3: ...ii...
Страница 22: ...0 1 CHAPTER 0 INTRODUCTION 0...
Страница 36: ...1 1 CHAPTER 1 INSTALLATION 1...
Страница 47: ...CHAPTER 1 INSTALLATION 1 12 Servo Amplifier 1...
Страница 48: ...2 1 CHAPTER 2 WIRING 2...
Страница 163: ...CHAPTER 2 WIRING 2 116 Safety Function 2...
Страница 164: ...3 1 CHAPTER 3 OPERATION 3...
Страница 192: ...4 1 CHAPTER 4 PARAMETER 4...
Страница 317: ...CHAPTER 4 PARAMETER 4 126 Extension Function 2 Setting Parameters 4...
Страница 318: ...5 1 CHAPTER 5 SERVO ADJUSTMENT 5...
Страница 353: ...CHAPTER 5 SERVO ADJUSTMENT 5 36 Special Adjustment Vibration Suppression 5...
Страница 354: ...6 1 CHAPTER 6 KEYPAD 6...
Страница 408: ...7 1 CHAPTER 7 MAINTENANCE AND INSPECTION 7...
Страница 434: ...8 1 CHAPTER 8 SPECIFICATIONS 8...
Страница 460: ...9 1 CHAPTER 9 CHARACTERISTICS 9...
Страница 472: ...10 1 CHAPTER 10 PERIPHERAL EQUIPMENT 10...
Страница 516: ...11 1 CHAPTER 11 ABSOLUTE POSITION SYSTEM 11...
Страница 523: ...CHAPTER 11 ABSOLUTE POSITION SYSTEM 11 8 Calculation of Battery Life 11...
Страница 524: ...12 1 CHAPTER 12 POSITIONING DATA 12...
Страница 540: ...13 1 CHAPTER 13 MODBUS RTU COMMUNICATION 13...
Страница 579: ...CHAPTER 13 MODBUS RTU COMMUNICATION 13 40 Communications Procedures 13...
Страница 580: ...14 1 CHAPTER 14 PC LOADER 14...
Страница 614: ...STANDARDS COMPLIANCE CHAPTER 15 15...
Страница 628: ...CHAPTER 16 APPENDIXES 16...
Страница 661: ...CHAPTER 16 APPENDIXES 34 Product Warranty 16 16 7 Product Warranty...
Страница 662: ......