![Fuji Electric ALPHA7 Скачать руководство пользователя страница 215](http://html1.mh-extra.com/html/fuji-electric/alpha7/alpha7_user-manual_2341766215.webp)
CHAPTER 4 PARAMETER
4-24
Basic Parameters
4
PA1_29 Speed coincidence range
No.
Name
Setting range
Default
value
Change
29
Speed coincidence range 10 [r/min] to max. rotation speed [r/min]
50
Always
Enter the range in which the "speed coincidence" output signal is turned on.
The speed coincidence signal is turned on if the actual servomotor rotation speed is nearly the
command speed.
In case of a default value of 50 [r/min], the speed coincidence signal is turned on in the range of ±50
[r/min] to the command speed.
If the command speed is not reached due to PA1_25 (maximum rotation speed), override or similar, the
signal is turned off.
The speed coincidence signal does not turn on if the [FWD] or [REV] signal is turned off.
For the speed coincidence signal, refer to "Speed coincidence [NARV]" 2.5.3 Signal
Descriptions.
PA1_30 Zero speed range
No.
Name
Setting range
Default
value
Change
30
Zero speed range
10 [r/min] to max. rotation speed [r/min]
50
Always
Enter the activation level of the "zero speed" output signal.
The signal is turned on at servomotor rotation speeds within the reference value.
PA1_31 Deviation unit selection
No.
Name
Setting range
Default
value
Change
31
Deviation unit selection
0: Unit amount [unit amount]
1: Pulse amount [pulse]
0
Always
Enter the unit of position deviation.
Select 0 (unit amount) for the unit after multiplication by the electronic gear ratio. [Unit] is displayed.
Select 1 (pulse amount) for the unit before multiplication by the electronic gear ratio. (Unit of encoder
pulse amount)
This setting is related to the unit of all position deviation monitored with the keypad, PC Loader or
monitor 1/2 signal.
Rotation speed
Time
PA1_29: Speed coincidence range
Forward command [FWD]
OFF
OFF
ON
OFF
ON
ON
Speed coincidence
[NARV]
Содержание ALPHA7
Страница 1: ......
Страница 3: ...ii...
Страница 22: ...0 1 CHAPTER 0 INTRODUCTION 0...
Страница 36: ...1 1 CHAPTER 1 INSTALLATION 1...
Страница 47: ...CHAPTER 1 INSTALLATION 1 12 Servo Amplifier 1...
Страница 48: ...2 1 CHAPTER 2 WIRING 2...
Страница 163: ...CHAPTER 2 WIRING 2 116 Safety Function 2...
Страница 164: ...3 1 CHAPTER 3 OPERATION 3...
Страница 192: ...4 1 CHAPTER 4 PARAMETER 4...
Страница 317: ...CHAPTER 4 PARAMETER 4 126 Extension Function 2 Setting Parameters 4...
Страница 318: ...5 1 CHAPTER 5 SERVO ADJUSTMENT 5...
Страница 353: ...CHAPTER 5 SERVO ADJUSTMENT 5 36 Special Adjustment Vibration Suppression 5...
Страница 354: ...6 1 CHAPTER 6 KEYPAD 6...
Страница 408: ...7 1 CHAPTER 7 MAINTENANCE AND INSPECTION 7...
Страница 434: ...8 1 CHAPTER 8 SPECIFICATIONS 8...
Страница 460: ...9 1 CHAPTER 9 CHARACTERISTICS 9...
Страница 472: ...10 1 CHAPTER 10 PERIPHERAL EQUIPMENT 10...
Страница 516: ...11 1 CHAPTER 11 ABSOLUTE POSITION SYSTEM 11...
Страница 523: ...CHAPTER 11 ABSOLUTE POSITION SYSTEM 11 8 Calculation of Battery Life 11...
Страница 524: ...12 1 CHAPTER 12 POSITIONING DATA 12...
Страница 540: ...13 1 CHAPTER 13 MODBUS RTU COMMUNICATION 13...
Страница 579: ...CHAPTER 13 MODBUS RTU COMMUNICATION 13 40 Communications Procedures 13...
Страница 580: ...14 1 CHAPTER 14 PC LOADER 14...
Страница 614: ...STANDARDS COMPLIANCE CHAPTER 15 15...
Страница 628: ...CHAPTER 16 APPENDIXES 16...
Страница 661: ...CHAPTER 16 APPENDIXES 34 Product Warranty 16 16 7 Product Warranty...
Страница 662: ......