ACCESSORIES
Optional Extension Cards
96
EMC-D42A Extension DC I/O Card:
This card adds four Digital Inputs, MI10–MI13
with COM common terminal and two polarity insensitive Transistor Outputs with
MXM common terminal.
MI10–MI13 inputs functionality is programmable through parameters
[OPTION–00 to 03]
.
Ratings are the same as VFD inputs MI1–MI8. The COM terminal should be connected
the same way as VFD COM terminal. For default VFD DIs configuration it should be
connected to +24V terminal.
MO10–MO11 outputs functionality is programmable through
[OPTION–00 to 03]
. Ratings
are 48 VDC at 50 mA maximum. The MXM terminal should be connected to the
common terminal of external power source and MO10 and MO11 to the load
(Example: PL pilot light on the diagram).
EMC-611A Extension AC Input Card:
This card adds six Digital Inputs, MI10–MI15 with AC
common terminal (Neutral).
MI10–MI13 inputs functionality is programmable through parameters
[OPTION–00 to 05]
.
Ratings are 100-130VAC, 47-63Hz, 27k impedance. Response time for ON is 10ms and for
OFF is 20ms.
EMC-R6AA Extension Relay Card:
This card adds six Relay Outputs, R10–R15 with SPST (single-pole single-
throw) form A (N.O.) contacts.
R10–R15 relay functionality is programmable through parameters
[OPTION–06 to 16]
.
Contact ratings for:
•
Resistive load 3A at 250VAC and 5A at 30VDC
•
Inductive load (COS 0.4) 1.2A at 250VAC and 2A at 30VDC
Содержание Cerus X-Drive
Страница 1: ...franklin electric com ENGLISH EN CERUSX DRIVE Installation and Operation Manual Firmware Version 1 1 ...
Страница 2: ......
Страница 3: ...CERUS X DRIVE INSTALLATION AND OPERATION MANUAL Firmware Version 1 1 Franklin Electric Co Inc ...
Страница 94: ...COMMUNICATIONS BACnet Communication 94 ...
Страница 98: ...ACCESSORIES Optional Extension Cards 98 Frame D Frame E Frame F ...
Страница 99: ...ACCESSORIES Optional Extension Cards 99 Frame G Frame H ...
Страница 102: ...ACCESSORIES Optional Extension Cards 102 ...