DRIVE PROGRAMMING
Default Settings Table - VFD Menu
51
Default Settings Table - VFD Menu
Parameters in highlighted rows are reset when the application is changed
[SET–00]
.
SET-48 High Load Level
110%
110%
110%
110%
110%
110%
110%
150%
110%
110%
SET-49 High Load Freq
20 Hz
20 Hz
20 Hz
20 Hz
20 Hz
30 Hz
20 Hz
20 Hz
40 Hz
60 Hz
SET-50 High Load Delay
2 Sec
2 Sec
2 Sec
2 Sec
2 Sec
2 Sec
2 Sec
2 Sec
2 Sec
5 Sec
SET-51
HLD Recovery T
0 Min
0 Min
0 Min
0 Min
0 Min
0 Min
0 Min
0 Min
0 Min
0 Min
SET-52 HLD Recovery Cnt Read Only Read Only Read Only Read Only Read Only
Read Only
Read Only Read Only Read Only Read Only
SET-53 ACC Change Freq
0 Hz
0 Hz
0 Hz
0 Hz
0 Hz
0 Hz
0 Hz
0 Hz
0 Hz
60 Hz
SET-54 Second ACC
60 Sec
60 Sec
60 Sec
60 Sec
60 Sec
60 Sec
60 Sec
60 Sec
60 Sec
5 Sec
SET-55 Second DCC
60 Sec
60 Sec
60 Sec
60 Sec
60 Sec
60 Sec
60 Sec
60 Sec
60 Sec
5 Sec
SET-56 ACC/DCC Hyster
1 Hz
1 Hz
1 Hz
1 Hz
1 Hz
1 Hz
1 Hz
1 Hz
1 Hz
1 Hz
SET-57 User Display
PID
Feedback
PID
Feedback
PID
Feedback
PID
Feedback
PID
Feedback
PID
Feedback
PID
Feedback
PID
Feedback
PID
Feedback
PID
Feedback
SET-58 PLC Menu
Disable
Disable
Disable
Disable
Disable
Disable
Disable
Disable
Disable
Disable
SET-59 ADV2 Menu Hide
Disable
Disable
Disable
Disable
Disable
Disable
Disable
Disable
Disable
Disable
SET-60 HOA Mode Source
Keypad
Keypad
Keypad
Keypad
Keypad
Keypad
Keypad
Keypad
Keypad
Keypad
CODE
Display
Basic
Supply Fan Exhaust
Fan
Cooling
Tower
Centrifugal
Pump
Submersible
Pump
Vacuum
Pump
Constant
Torque
PM Motor
MagForce
CODE
Display
Basic
Supply Fan Exhaust
Fan
Cooling
Tower
Centrifugal
Pump
Submersible
Pump
Vacuum
Pump
Constant
Torque
PM Motor
MagForce
VFD-00 VFD Max Freq
60 Hz
60 Hz
60 Hz
60 Hz
60 Hz
60 Hz
60 Hz
60 Hz
115Hz
115 Hz
VFD-01
VFD Start Freq
0.50 Hz
0.50 Hz
0.50 Hz
0.50 Hz
0.50 Hz
0.50 Hz
0.50 Hz
0.50 Hz
0.50 Hz
0.50 Hz
VFD-02 VFD Base Freq
60 Hz
60 Hz
60 Hz
60 Hz
60 Hz
60 Hz
60 Hz
60 Hz
120 Hz
120 Hz
VFD-03 V/F Pattern
Linear
Linear
Linear
Linear
Linear
Linear
Linear
Linear
Linear
Linear
VFD-04 Step Freq-1
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
VFD-05 Step Freq-2
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
VFD-06 Step Freq-3
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
VFD-07 Step Freq-4
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
VFD-08 Step Freq-5
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
VFD-09 Step Freq-6
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
VFD-10
Step Freq-7
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
VFD-11
Step Freq-8
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
VFD-12
Step Freq-9
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
VFD-13
Step Freq-10
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
VFD-14
Step Freq-11
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
VFD-15
Step Freq-12
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
VFD-16
Step Freq-13
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
VFD-17
Step Freq-14
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
VFD-18
Step Freq-15
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
VFD-19
ACC-2 Time
40 Sec
40 Sec
40 Sec
40 Sec
40 Sec
2 Sec
40 Sec
40 Sec
40 Sec
2 Sec
VFD-20 DEC-2 Time
40 Sec
40 Sec
40 Sec
40 Sec
40 Sec
2 Sec
40 Sec
40 Sec
40 Sec
2 Sec
VFD-21
ACC-3 Time
60 Sec
60 Sec
60 Sec
60 Sec
60 Sec
60 Sec
60 Sec
60 Sec
60 Sec
60 Sec
VFD-22 DEC-3 Time
60 Sec
60 Sec
60 Sec
60 Sec
60 Sec
60 Sec
60 Sec
60 Sec
60 Sec
60 Sec
VFD-23 ACC-4 Time
30 Sec
30 Sec
30 Sec
30 Sec
30 Sec
30 Sec
30 Sec
30 Sec
30 Sec
30 Sec
VFD-24 DEC-4 Time
40 Sec
40 Sec
40 Sec
40 Sec
40 Sec
40 Sec
40 Sec
40 Sec
40 Sec
40 Sec
VFD-25 S Start Time 1
0 Sec
0 Sec
0 Sec
0 Sec
0 Sec
0 Sec
0 Sec
0 Sec
0 Sec
0 Sec
VFD-26 S Start Time 2
0 Sec
0 Sec
0 Sec
0 Sec
0 Sec
0 Sec
0 Sec
0 Sec
0 Sec
0 Sec
VFD-27 S End Time 1
0 Sec
0 Sec
0 Sec
0 Sec
0 Sec
0 Sec
0 Sec
0 Sec
0 Sec
0 Sec
VFD-28 S End Time 2
0 Sec
0 Sec
0 Sec
0 Sec
0 Sec
0 Sec
0 Sec
0 Sec
0 Sec
0 Sec
VFD-29 Skip Freq 1 High
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
VFD-30 Skip Freq 1 Low
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
VFD-31
Skip Freq 2 High
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
VFD-32 Skip Freq 2 Low
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
0.0 Hz
Содержание Cerus X-Drive
Страница 1: ...franklin electric com ENGLISH EN CERUSX DRIVE Installation and Operation Manual Firmware Version 1 1 ...
Страница 2: ......
Страница 3: ...CERUS X DRIVE INSTALLATION AND OPERATION MANUAL Firmware Version 1 1 Franklin Electric Co Inc ...
Страница 94: ...COMMUNICATIONS BACnet Communication 94 ...
Страница 98: ...ACCESSORIES Optional Extension Cards 98 Frame D Frame E Frame F ...
Страница 99: ...ACCESSORIES Optional Extension Cards 99 Frame G Frame H ...
Страница 102: ...ACCESSORIES Optional Extension Cards 102 ...