DRIVE PROGRAMMING
Default Settings Table - ADV2 Menu
59
Default Settings Table - ADV2 Menu
Parameters in highlighted rows are reset when the application is changed
[SET–00]
.
CODE
Display
Basic
Supply Fan Exhaust Fan Cooling
Tower
Centrifugal
Pump
Submersible
Pump
Vacuum
Pump
Constant
Torque
PM Motor
MagForce
ADV2-00 PID D-Gain
0 Sec
0 Sec
0 Sec
0 Sec
0 Sec
0 Sec
0 Sec
0 Sec
0 Sec
0 Sec
ADV2-01 Sleep Ctrl By
PID
Output
PID Output PID Output PID Output PID Output PID Output
PID Output PID Output PID Output PID Output
ADV2-03 Mtr Brake Delay
0 Sec
0 Sec
0 Sec
0 Sec
0 Sec
0 Sec
0 Sec
0 Sec
0 Sec
0 Sec
ADV2-04 AFM1 Rev Value
0-10 V
0-10 V
0-10 V
0-10 V
0-10 V
0-10 V
0-10 V
0-10 V
0-10 V
0-10 V
ADV2-05 AFM2 Rev Value
0-10 V
0-10 V
0-10 V
0-10 V
0-10 V
0-10 V
0-10 V
0-10 V
0-10 V
0-10 V
ADV2-06 AFM1 DC Lvl
50%
50%
50%
50%
50%
50%
50%
50%
50%
50%
ADV2-07 AFM2 DC Lvl
50%
50%
50%
50%
50%
50%
50%
50%
50%
50%
ADV2-08 Analog Curve
3x AIs 3-
Point
3x AIs 3-
Point
3x AIs 3-
Point
3x AIs 3-
Point
3x AIs 3-
Point
3x AIs 3-
Point
3x AIs 3-
Point
3x AIs 3-
Point
3x AIs 3-
Point
3x AIs 3-
Point
ADV2-09 AVI1 Low Value
0
0
0
0
0
0
0
0
0
0
ADV2-10 AVI1 Low %
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
ADV2-11 AVI1 Mid Value
5
5
5
5
5
5
5
5
5
5
ADV2-12 AVI1 Mid %
50%
50%
50%
50%
50%
50%
50%
50%
50%
50%
ADV2-13 AVI1 High Value
10
10
10
10
10
10
10
10
10
10
ADV2-14 AVI1 High %
100%
100%
100%
100%
100%
100%
100%
100%
100%
100%
ADV2-15 ACI Low Value
4
4
4
4
4
4
4
4
4
4
ADV2-16 ACI Low %
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
ADV2-17 ACI Mid Value
12
12
12
12
12
12
12
12
12
12
ADV2-18 ACI Mid %
50%
50%
50%
50%
50%
50%
50%
50%
50%
50%
ADV2-19 ACI High Value
20
20
20
20
20
20
20
20
20
20
ADV2-20 ACI High %
100%
100%
100%
100%
100%
100%
100%
100%
100%
100%
ADV2-21 AVI Low Value
0 V
0 V
0 V
0 V
0 V
0 V
0 V
0 V
0 V
0 V
ADV2-22 AVI Low %
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
ADV2-23 AVI Mid Value
5 V
5 V
5 V
5 V
5 V
5 V
5 V
5 V
5 V
5 V
ADV2-24 AVI Mid %
50%
50%
50%
50%
50%
50%
50%
50%
50%
50%
ADV2-25 AVI High Value
10 V
10 V
10 V
10 V
10 V
10 V
10 V
10 V
10 V
10 V
ADV2-26 AVI High %
100%
100%
100%
100%
100%
100%
100%
100%
100%
100%
ADV2-27 dEb Offset V
By VFD
Rating
By VFD
Rating
By VFD
Rating
By VFD
Rating
By VFD
Rating
By VFD
Rating
By VFD
Rating
By VFD
Rating
By VFD
Rating
By VFD
Rating
ADV2-28 dEb Mode Select
Disable
Disable
Disable
Disable
Disable
Disable
Disable
Disable
Disable
Disable
ADV2-30 PID Mode Select
Serial
Serial
Serial
Serial
Serial
Serial
Serial
Serial
Serial
Serial
ADV2-31 PID Unit Format
0.01
0.01
0.01
0.1
0.1
0.1
0.1
0.1
0.1
0.1
ADV2-32 PID Ref Source
Keypad
Keypad
Keypad
Keypad
Keypad
Keypad
Keypad
Keypad
Keypad
Keypad
ADV2-52 LD Set Point
0.5 (unit) 0.5 (unit)
0.5 (unit)
70 (unit)
70 (unit)
70 (unit)
70 (unit)
70 (unit)
70 (unit)
70 (unit)
ADV2-53 LD Max Freq
48 Hz
48 Hz
48 Hz
48 Hz
48 Hz
48 Hz
48 Hz
48 Hz
96 Hz
96 Hz
Содержание Cerus X-Drive
Страница 1: ...franklin electric com ENGLISH EN CERUSX DRIVE Installation and Operation Manual Firmware Version 1 1 ...
Страница 2: ......
Страница 3: ...CERUS X DRIVE INSTALLATION AND OPERATION MANUAL Firmware Version 1 1 Franklin Electric Co Inc ...
Страница 94: ...COMMUNICATIONS BACnet Communication 94 ...
Страница 98: ...ACCESSORIES Optional Extension Cards 98 Frame D Frame E Frame F ...
Страница 99: ...ACCESSORIES Optional Extension Cards 99 Frame G Frame H ...
Страница 102: ...ACCESSORIES Optional Extension Cards 102 ...