FT-111(D) Panel Weighing Indicator, Technical Manual, Rev.1.0.0, May 2019
Page
76
of
146
VIN-LOW
Window, active low
Output goes to low if absolute indicated weight
is between setpoint high and setpoint low.
S IND Free setpoint of indicated weight
The digital output is activated with comparing the set point value and indicated weight value as seen
below.
As an example,
if SP1
SP1
LOW
SP1
HIGH
SP2
SP2
LOW
SP2
HIGH
= 100 kg or
= 100 kg
= 150 kg
= -200kg or
= -200kg
= -225kg
BAS-HI
Basic, active high
Output is high if indicated weight is heavier
than setpoint.
( Default )
BAS-LO
Basic, active low
Output is low if indicated weight is heavier
than setpoint.
THR-HI
Threshold, active high
Output goes to high if indicated weight is
heavier than setpoint high. Returns the low if
the weight is less than setpoint low.