19- ETHERNET IP
]
ETHERNET/IP CONFIGURATION
(Only FT-111 EI)
Press key or
key again to enter this menu.
Press
key to go to beginning of the sub-block or press
key to go to the next main-block.
[
191 FORMAT
: INTG ]
Data format of the EtherNet/IP
INTG
FLOA
:
:
Signed 32 bit integer, no decimal point
implied.
32 bit float, decimal point implied.
[
192 IP
:
250 ]
IP address of Ethernet port.
Default is 192.168.16.250
[
194 SUB MASK :
000 ]
Subnet mask address of Ethernet port.
Default is 255.255.255.000
[
195 GATEWAY :
253 ]
Gateway address.
Default is 192.168.16.253
[
19A MAC ADR
:
]
MAC address
AA:BB:CC:DD:EE:FF
[
19- ETHERCAT
]
ETHERCAT CONFIGURATION
(Only FT-111 EC)
Press key or
key again to enter this menu.
Press
key to go to beginning of the sub-block or press
key to go to the next main-block.
[
191 FORMAT
: INTG ]
Data format of the EtherCAT
INTG
FLOA
:
:
Signed 32 bit integer, no decimal point implied.
32 bit float, decimal point implied.
[
19- CC-LINK
]
CC-LINK CONFIGURATION
(Only FT-111 CC)
Press key or
key again to enter this menu.
Press
key to go to beginning of the sub-block or press
key to go to the next main-block.
[
191 FORMAT
: INTG ]
Data format of the CC-Link
INTG
FLOA
:
:
Signed 32 bit integer, no decimal point implied.
32 bit float, decimal point implied.
[
192 ADDRESS
:
001 ]
Node address
001…64
[
193 BAUD
: 156K ]
Baud rate
156K
625K
2.5M
5M
10M
:
:
:
:
:
156 kbps
625 kbps
2.5 Mbps
5 Mbps
10 Mbps