FT-111(D) Panel Weighing Indicator, Technical Manual, Rev.1.0.0, May 2019
Page
47
of
146
1200
2400
4800
9600
:
:
:
:
1200 19K2 : 19200
2400 38K4 : 38400
4800 57K6 : 57600
9600
[
133 LENGHT
:
8 ]
Data Length
7
8
:
:
7 bits
8 bits
[
134 PARITY
:
NO ]
Parity
NO
ODD
EVEN
:
:
:
No parity
Odd parity
Even parity
[
135 CSUM
:
NO ]
Checksum at continuous and BSI formats.
NO
YES
:
:
Checksum disable
Checksum enable
[
136 CR
:
YES ]
Carriage return at continuous formats.
NO
YES
:
:
Carriage return disable
Carriage return enable
[
137 LFEED
:
YES ]
Line feed at continuous formats.
NO
YES
:
:
Line feed disable
Line feed enable
[
138 DELAY
:
50 ]
Data output delay at Modbus and BSI formats; delay between
continuous format data.
000 …. 999 milliseconds.
[
139 ADDRESS
:
00 ]
Address of the port
00 …. 99.
00 means data format without address.
[
13A DUBLEX
: HALF ]
Duplex on the interface
HALF
FULL
:
:
Half duplex ( select for RS485 )
Full duplex
[
14- USB
]
USB
Press key or
key again to enter this menu.
Or press
key to go to the next sub-block.
[
141 FORMAT
:
NO ]
Data format of the serial port
NO
CONT
FAST
BSI
:
:
:
:
Port is disabled
Continuous data output
High speed continuous data output
BSI format for PC, PLC interface
Press
key to select output format different than Flintec
continuous data format while the selection is CONT in the
information display. Available functions are seen on the weight
display after pressing
key sequentially. Press
key after
selecting the data format.
Refer to Appendix 5 for details data structure.
[
FLINTEC
]
FLINTEC
HBM
TOLEDO
:
:
:
Flintec continuous format.
Commonly used by HBM, GSE, PT, Systec, Rinstrum.
Commonly used by Toledo, Mettler Toledo.