FT-111(D) Panel Weighing Indicator, Technical Manual, Rev.1.0.0, May 2019
Page
87
of
146
HBM
®
Description
STX Sign Indicated weight
S1
S2
S3
S4
Unit
ETX
Example
☻
0
.
7
5
0
N
1
k
g
♥
Toledo
®
Description
STX A
B
C
Indicated weight
Tare weight
CR LF CHK
Example
☻
}
1
0
0
7
5
0
2
5
0
♠
SysTec
®
Description
Status
Indicated weight
SP Unit
CR LF
Example
S
0
.
7
5
0
k
g
SMA
Description
LF
S
R
N
M
F
Indicated weight
Unit
CR
Example
1
N
0
.
7
5
0
k
g
Function
Description
LF
Line Feed ( 0A hex )
S
Z = Centre of zero,
O = Over cap,
U = Under cap,
E = Weight not currently being displayed.
“ “
(space)
= None of the above conditions.
R
Range.
1 = First range,
2 = Second range,
3 = Third range.
N
Mode.
G = Gross weight,
T = Tare weight,
N = Net weight,
g = Gross weight in increased resolution.
n = Net weight in increased resolution.
M
Motion.
M = Motion,
“ “
(space)
= No motion.
F
Always a space as ASCII ( 20 hex ).
Indicated Weight
These ten characters are a string containing the current weight including
the decimal point.
Unit
Unit of weight value are kg, g, lb, klb, N or kN as left aligned.
CR
Carrige Return ( 0D hex )
Sartorious
®
Description
Ignore
Sign SP Indicated weight
SP Unit
CR LF
Example
+
0
.
7
5
0
k
g