FT-111(D) Panel Weighing Indicator, Technical Manual, Rev.1.0.0, May 2019
Page
138
of
146
Expanded Command List
The “B48…B55” bits in RxPDO describes below.
Bit No
Description
B23…B16
Expanded
Commands
List
Bin
Dec
Commands
00000000
0
R
Voltage of power supply
(2)
The value is indicated with 0.1 VDC increment.
00000001
1
R
Load cell millivolt value
(2)
(Only FT-111 )
Millivolt of active scale is indicated with 0.01
mV increment.
00000010
2
R
Command status
(2)
Dec
Descr. of 1st Dword
0
None
1
Command is processing
2
Command is done
3
Command failed
00000011
3
R/W
Reprint the last
label
(1) (2)
0
None
1
Reprint the last label
00000100
4
R/W
High resolution
(1) (2)
0
Enable
1
Disable
00000101
5
W
Unit change
(1)
0
From first to second unit
1
From second to first unit
00000110
6
R/W
Key lock
(1) (2)
0
Enable
1
Disable
00000111
7
W
Dynamic
operation
(1)
0
Dynamic reset
1
Dynamic start
0000100000
001011
8
11
Not used
00001100
12
R/W
Basic Peak
0
Enable
1
Disable
00001101
13
R/W
Hold
0
Enable
1
Disable
00001110
00111110
14
62
Not used
00111111
63
R/W
Dynamic filter
(1) (2)
Refer to par. 332 page 57
01000000
64
R/W
Filter
(1) (2)
0
No
1
Very Low
2
Low
3
Medium
4
High
5
Very High
01000001
65
R/W
Power on zero
(1) (2)
0
Disable
1
± %2
2
± %2LK
3
± %10
4
+ %15, - %5
5
± %20
01000010
66
R/W
Zeroing Range
(1) (2)
0
Disable
1
± 2%
2
± 3%
3
± 20%
4
± 50%
01000011
67
R/W
Auto Zero
Tracking
(1) (2)
0
Disable
1
± 0,3d
2
± 0,5d
3
± 1d
4
± 2d
5
± 3d
01000100
68
R/W
Tare
(1) (2)
0
No
1
Multi tare
2
Tare only at gross
01000101
69
R/W
Stability
Detection
Range
(1) (2)
0
± 0,3d
1
± 0,5d
2
± 1d
3
± 2d