FT-111(D) Panel Weighing Indicator, Technical Manual, Rev.1.0.0, May 2019
Page
125
of
146
ALL Status ( always 32 bit integer )
1
st
Dword (input) descriptions when read command is ‘ALL Status’.
Refer to 2
nd
Dword of PLC Output to FT-111 Input.
Bit Number
1
st
Dword (input) Description
B31
Place of decimal point
0
None
1
No decimal point
B30
0
None
1
Decimal point is X.X
B29
0
None
1
Decimal point is X.XX
B28
0
None
1
Decimal point is X.XXX
B27
0
None
1
Decimal point is X.XXXX
B26 … B16
Not in use
B15
Hold status
0
Passive
1
Active
B14
Basic Peak status
0
Passive
1
Active
B13
High resolution status
0
Passive
1
Active
B12
Centre of zero
0
Weight is out of zero range
1
Weight is in zero range
B11
Key lock status
0
Passive
1
Active
B7-B10
Not used
B6
Unit indication
0
First Unit (power on unit)
1
Second Unit
B5
Power On Zero
0
Not power on zeroed
1
Zeroed with power on zero
B4
Not in use
B3
Indication
0
Gross mode
1
Net mode
B2
Motion Detection
0
Stable
1
Unstable
B1
Actual Weight or
Dynamic Result
0
Weight is actual weight
1
Weight is dynamic result
B0
Dynamic Operation
0
Dynamic is inactive
1
Dynamic weight is calculating
Table 11-1
– ALL Status table