FT-111(D) Panel Weighing Indicator, Technical Manual, Rev.1.0.0, May 2019
Page
84
of
146
Entry the limit values
1. Press the
key.
2. The setpoint 1 value appears as shown on the display [ SP 1 1250 kg ].
3. Press
key to increase or press
key to decrease the blanking digit and press or key to
select a digit. You may press
key to enter negative setpoint value. Press the
key to save it
and to go to the next setpoint.
4. Repeat from step 2 for entering following setpoints.
5. The indicator returns to the operation after displaying setpoint 5 and entering its value,
6. Press
key to return operation at any step.
Entry setpoint of items into SET memory
1. Press
key for more than 2 seconds. [ MEMORY ] prompt appears.
2. Press
key. The last used Set memory group number appears [ SET : 111 ].
3. Enter the new memory code by pressing
key to increase or press
key to decrease the
blanking digit and press or key to select a digit and press
key to enter the item.
4. The first limit value is appear on the display as [ SET 111 - SP1 ] [ 10.00 kg ]. Enter the new value
by numerical keys and press the
key.
5. The following limit value appears as [ SET 111 - SP2 ] [ 20.00 kg ]. Enter new value by pressing
key to increase or press
key to decrease the blanking digit and press or key to select
digit and press the
key.
6. Repeat step 4 and 5 until entering values to other three limit value of the group.
7. After entering the value of 5th setpoint value press
key to go next memory code.
8. Or press
key to exit.
Select limits of item from SET memory
1. Press
key. The last used setpoint value appears on the display [ SP1 1250 kg ].
2. Press
key for more than 2 seconds. The last used Set memory code appears on the display
[ SET : 111 ].
3. Enter the memory code of the item by pressing
key to increase or press
key to decrease
the blanking digit and press or key to select a digit and press
key.
4. The selected Set memory data is loaded after displaying values.
5. Or press
key to exit without loaded.