25
000859CG-F
2 - Characteristics
Table: Technical Data
PVS-60-TL
Input
Absolute Maximum Input Voltage (Vmax,abs)
1000 V
Input start-up voltage (Vstart)
420...700 V (Default 500 V)
DC Input operating interval (Vdcmin...Vdcmax)
0,7xVstart...950 V (min 360 V)
Rated DC Input Voltage (Vdcr)
720 V
DC Input Nominal Power(Pdcr)
61800 W
Number of Independent MPPT
3 (-SX and -SX2 version) / 1 (standard and -S version)
Max DC Input power for each MPPT
(PMPPT,max)
23100 W@30°C/21000 W@45°C
MPPT DC Voltage Range
(VMPPTmin ... VMPPTmax) to Pacr
570...800 V
Maximum DC Input Current (Idcmax)
for each MPPT
36 A
Maximum Return current (AC side vs DC side)
Negligible in normal operating conditions
(3)
Max short circuit current (Iscmax) for each MPPT
55 A (165A in case of parallel MPPTs)
Number of DC Connection Pairs for each MPPT
5 (-SX and -SX2 version)
Type of Input DC Connectors Screw terminal block max. cross-section 95mm
2
(Standard and -S version)
PV quick fit connector
(4)
(-SX and -SX2 version)
Type of photovoltaic panels that can be con-
nected at input according to IEC 61730
Class A
Input protection
Reverse Polarity Protection
Yes, from current limited source
Input overvoltage protection for each MPPT -
SPD
Yes, 1 for each MPPT
Input overvoltage protection for each MPPT -
surge arrester
Type II / Type I+II (optional)
Isolation Check
Complying with the local standard
Characteristics of DC disconnect switch for each
MPPT (versions with DC disconnect switch) 1000 V / 60 A for each MPPT (180 A in case of parallel MPPTs)
String fuses (-SX/-SX2 versions)
15A (gPV / 1000Vdc)
(6)
Output
AC Connection to the grid
3W + GND (no N connection) or 4W + GND (with N connection)
Grounded WYE system only
Nominal AC Output Power (Pacr @cosφ=1)
60000 W
Maximum AC Output Power (Pacmax @cosφ=1)
66000 W up to 30°C
Maximum apparent Output power (Smax)
66000 VA up to 30°C
Rated AC Output Voltage (Vacr)
480 Vac
Output voltage range (Vacmin...Vacmin)
384...571 Vac
(1)
Maximum output current (Iacmax)
80 A
Contribution to short-circuit current
92 A
Rated Output Frequency (fr)
50 Hz / 60 Hz
Output Frequency Range (fmin...fmax)
47...53 Hz / 57…63 Hz
(2)
Nominal power factor and setting interval
> 0.995, 0...1 inductive/capacitive with maximum Smax
Total harmonic distortion of current
<3%
Max AC cable cross section accepted
95 mm
2
copper/aluminum
AC Connections Type
Screw terminal block - single AC cable gland M63
Output protection
Anti-islanding Protection Complying with the local standard (active frequency drift combined
with RoCoF techniques)
Maximum external AC overcurrent protection
100 A
Output overvoltage protection - Varistors
Yes
Output overvoltage protection - Modular surge
arrester
Type 2
Operating performance
Maximum Efficiency (ηmax)
98.6%