24
000859CG-F
2 - Characteristics
Table: Technical Data
PVS-50-TL
Output overvoltage protection - Modular surge
arrester
Type II
Operating performance
Maximum Efficiency (ηmax)
98.4%
Weighted Efficiency (EURO/CEC)
98.2% / -
Communication
Embedded communication interface 3x RS485, 2x Ethernet (RJ45), WLAN (IEEE802.11 b/g/n @ 2,4 GHz)
Communication protocol
Modbus RTU / TCP (Sunspec compliant); Aurora Protocol
Remote Monitoring services
Standard level access to Aurora Vision monitoring portal
Advanced features Integrated Web User Interface; Display (option); Embedded logging
and direct transferring of data to Cloud
Environmental
Ambient temperature range
-25...+60°C (-13...140°F) with derating over 45°C (113°F)
Relative Humidity
4…100 % condensing
Typical noise emission pressure
75 dB(A) @ 1 m
Maximum operating altitude
4000 m (13123 ft) with derating above 2000 m / 6561 ft
Environmental pollution degree
classification for external environments
3
Environmental class
Outdoor
Physical
Environmental Protection Rating
IP 65 (IP54 for the cooling section)
Cooling System
Forced air
Dimensions (H x W x D)
750 mm x 1100 mm x 257 mm / 29.5” x 43.3” x 10.12”
Weight
70 kg / 154 lbs (SX version)
Assembly System
Mounting bracket (vertical or horizontal)
Overvoltage rating as per IEC 62109-1
II (DC input) III (AC output)
Safety
Safety class
I
Isolation Level
Transformerless (TL)
CE Marking
CE
(5) (7)
Safety and EMC Standards
IEC/EN 62109-1, IEC/EN 62109-2, EN 61000-6-2,
EN 61000-6-3, EN 61000-3-11, EN 61000-3-12
Grid standard (check the availability with your
sales channel)
CEI 0-21, CEI 0-16, DIN V VDE V 0126-1-1,
VDE-AR-N 4105, G59/3, EN 50438 (not for all national appendices),
RD 1699, RD 413, RD 661, P.O. 12.3, AS 4777, BDEW, NRS-097-
2-1, MEA, PEA, IEC 61727,
IEC 60068, IEC 61683, VFR-2014, IEC 62116
Accessories
PVS-50/60-GROUNDING KIT
Allows to connect the negative input pole to ground
DISPLAY
Display is available as optional by dedicated part number
1. The output voltage range may vary according to the grid standard of the country of installation
2. The output frequency range may vary according to the grid standard of the country of installation
3. In the event of a fault, limited by the external protection envisaged on the AC circuit
4. Please refer to the document “String inverters – Product manual appendix” available at www.fimer.com for information on the
quick-fit connector brand and model used in the inverter.
5. 50Hz only
6. Maximum installable size 20A
7. Hereby, Power-One Italy S.p.A. (A Member of the FIMER Group) declares that the radio equipments (radio module combined with
the inverter), to which this user manual refers, are in compliance with the Directive 2014/53/EU. The full text of the EU Declaration of
Conformity is available at the following internet address: www.fimer.com
Note. Features not specifically mentioned in this data sheet are not included in the product
Содержание PVS-50-TL
Страница 1: ...Product Manual PVS 50 TL PVS 60 TL from 50 to 60 kW ...
Страница 139: ...139 000878BG F 7 Operation ...