108
000877BG-F
7 - Operation
Description of the Web User Interface
The inverter is equipped with an advanced integrated Web User Inter-
face and user interface that allow a full access to all configuration and
comissioning parameters from any electronic device (laptop, tablet and
smartphone).
Access to the Web User Interface
To access to the Web User Interface is required to connect a device
equipped with wireless connection (such as tablet, laptop or smartphone).
Depending on the connection method choosen during the inverter com-
missioning phase (“Station Mode” or “AP Mode”) it’s required to follow
one of the two procedures described below:
Connection to the inverter in “Station Mode”
• Enable the wireless connection on the device (tablet, smartphone or
laptop) and connect it to the same wireless network to which the inverter
is connected.
• Open an internet browser (reccomended browser: Chrome versions
from v.55, Firefox versions from v.50) and enter the links (corresponding
to the IP Address assigned by the router to the inverter, or the “Host
Name”) provided during the commissioning phase to access the login
page.
In order to use the “Host Name” as an alternative to the dynamic IP address, the Wi-Fi router
to which the board is connected (when operating in “Station Mode”) must provide the Domain
Name System (DNS) service (contact the network administrator for further information regar-
ding the presence or absence of the DNS service in the Wi-Fi router or how to enable it). In this
way, even if the IP address assigned to the inverter should change over time, (dynamic IP), it
will always be possible to use the same “Host Name” which will remain unchanged over time.
The IP address assigned may vary for reasons connected to the wireless home router setup
(for example, a very brief DHCP lease time). If verification of the address is required, it is
usually possible to obtain the client list (and the corresponding IP addresses) from the wire-
less router administration panel.
If the “Host Name” was lost, it could be obtained writing this url:
http://ABB-XX-XX-XX-XX-XX-XX.local
replacing the “
X” with the hex digits of the MAC address of the inverter (it can be found on the
“Communication Identification label” placed on the side of the inverter or applied during the
commissioning phase to the plant documentation).