![background image](http://html1.mh-extra.com/html/fbii/omni-400-eu/omni-400-eu_installation-and-setup-manual_547062067.webp)
Section 6. System Programming
6-31
Q 20, L2
— Enter the L2 digit from the table below.
L2
Entry
Keypad
Tamper
Enable
Keypad
Tamper
Sounder
Keypad
Tamper
Bell
0
1
✔
3
✔
✔
5
✔
✔
7
✔
✔
✔
Keypad Tamper Enable: If enabled, the system will monitor
the keypads for a keypad tamper report. If a keypad tamper is
reported by a keypad, a report will be sent to the central station
if enabled in Submode 2, Question 25, Locations 3 and 4.
Keypad Tamper Sounder: If enabled, the keypad sounder
will sound on a keypad tamper condition.
Keypad Tamper Bell: If enabled, the bell will sound on a
keypad tamper condition.
NOTE: Keypad tamper is only available on some OMNI-LCD and OMNI-KP keypads. Refer to your
keypad instructions to see if your keypad has keypad tamper reporting capabilities
QUESTION 21 AUTO-ARM TIME
L1 L2
L3 L4
This question sets the auto-arming time.
Hours (00-23)
Minutes (00-59)
L1/L2: Enter hour 00–23 by entering the first digit of the hour (0–2) in L1 and the second digit (0–9) of
the hour in L2. (00 = 12 midnight)
L3/L4: Enter minute 00–59 by entering the first digit of the minute (0-5) in L3 and the second digit (0-
9) of the minute in L4.
For example, to set an auto-arm time of 11:35pm, enter 2 in L1 and 3 in L2, then enter 3 in L3 and 5 in
L4.
UL
Must be disabled for UL installations.
QUESTION 22 CENTRAL STATION TEST TIME
L1 L2
L3 L4
This question sets the central station test time.
Hours (00-23)
Minutes (00-59)
L1/L2: Enter hour 00–23 by entering the first digit of the hour (0–2) in L1 and the second digit (0–9) of
the hour in L2. (00 = 12 midnight)
L3/L4: Enter minute 00–59 by entering the first digit of the minute (0-5) in L3 and the second digit (0-
9) of the minute in L4.
For example, to set a central station test time of 11:35pm, enter 2 in L1 and 3 in L2, then enter 3 in L3
and 5 in L4.
QUESTIONS 23–29 TRIGGER/RELAY TYPES
These questions set the relay and trigger types. Momentary trigger times in minutes or seconds are set
in Submode 1, Question 30, L1 and L2 (minutes), or L3 and L4 (seconds).
Each trigger/relay definition requires two locations to define its operation. Note that all momentary
triggers will follow the momentary time (seconds or minutes) programmed in Question 30.
NOTE: Triggers 3 and 4 are used for the XL4705 relay module if selected in Question 09, L2. Make
entries from the table that follows.
Содержание OMNI-400 EU