Section 5. System Operation
5-13
DISPLAY AUTO-ARM TIME (LCD KEYPADS ONLY): # 52
If auto-arming is programmed, pressing [#] [5] [2] displays the current auto-arm time for the current
area on the LCD keypads.
NOTE:
Auto-arming is enabled in programming Submode 1, Question 20,
L1 and the auto-arm time is set by using [#] [5] [4]. The keypad displays:
AUTO ARM TIME:
12:00AM
The system exits this mode either automatically (no keys pressed), or when the star [
✱
] key is pressed.
SET AUTO-ARM TIME: # 54
If auto-arming is enabled in programming Submode 1, Question 20, pressing [#] [5] [4] will set the
auto-arm time. If a user code is required to set the time, then enter:
[#] + [5] + [4] + USER + HOUR + MINUTE
where: USER
Valid 4- or 6-digit user code
HOUR
Two-digit hour of day in 24 hour format; e.g., 7AM = 07; 3PM = 15
MINUTE Two-digit minutes of hour; e.g., 9 min = 09; 29 min. = 29
If a user code is not required to set the time, then enter:
[#] + [5] + [4] + HOUR + MINUTE
In either case, the LCD keypads will display a prompt for each entry. On LED keypads, the sounder
will beep after each entry. The auto-arm time represents the time of day that the panel will
automatically arm if it is not already armed. In addition, it can be programmed to arm in the STAY or
INSTANT mode and an audible warning (4 quick beeps) can be generated at the keypad starting 3
minutes prior to arming, if programmed in Submode 1, Question 20, L1. This signal (which reoccurs
once every minute) warns the occupants that the system will auto-arm in 3 minutes. If a user code is
entered within this warning period and the system is disarmed, the auto-arm time for that day will be
canceled. The system will generate an audible acknowledgment (1-second keypad sounder) and the
lights on the LED display will scroll to show that the auto-arm time was suspended. LCD-based
keypads will display “AUTO-ARM CANCELED.”
The system will exit this mode either automatically (no keys pressed) after the last entry (MINUTE), or
when the star [
✱
] key is pressed.
NOTE: Auto-arming will arm the system and bypass any zones that are not ready. Therefore, we
recommend that you report bypasses to the CS if auto-arming is programmed. Auto-arming is not
suitable for UL applications.
UL
Auto arming is not suitable for UL applications.
LOSS-OF-TIME WARNING:
If auto-arming has been enabled and no time is defined, a warning will
appear on the keypads if enabled in Submode 1, Question 13, Location 3. This can occur if time (#3
command) has not been entered or if the system has totally lost power (AC and DC) and the time is
probably incorrect. The loss-of-time warning consists of the LEDs on the keypads scrolling in
sequence or a text message on LCD keypads. This will occur every 30 seconds until the time is set.