Section 6. System Programming
6-25
QUESTION 14 LOG OPTIONS
L1 L2 L3 L4
This question defines event log options. Enter the digits as follows:
Q 14, L1
— Enter the L1 digit from the table below.
L1
Entry
Enable #53
Log Command
Log Zone
Alarms
Log Zone
Troubles
0
1
✔
4
✔
5
✔
✔
8
✔
9
✔
✔
C
✔
✔
D
✔
✔
✔
Enable #53 Log Command: If selected, users
will be able to view the log using the #53
command.
Log Zone Alarms/Troubles: If selected, alarms
and troubles will be included in the event log.
Q14, L2
— Enter the L2 digit for the desired events to be recorded in event log.
L2
Entry
Log
Open
Log
Close
Log System
Events
Log Key
Events
0
1
✔
2
✔
3
✔
✔
4
✔
5
✔
✔
6
✔
✔
7
✔
✔
✔
8
✔
9
✔
✔
A
✔
✔
B
✔
✔
✔
C
✔
✔
D
✔
✔
✔
E
✔
✔
✔
F
✔
✔
✔
✔
Q14, L3—
Enter the L3 digit for the desired events to be recorded in event log.
L3
Entry
Log Keypad
Supervision
Log
Tamper
Log
Bypass
0
2
✔
4
✔
6
✔ ✔
8
✔
A
✔ ✔
C
✔
✔
E
✔ ✔
✔
NOTES:
Log Keypad Supervision causes a log entry of “Supervise
LCD 1-8 and LED/FW 1-8” if a supervised keypad is
removed from the system. Keypad supervision is available
for the XK-7LC, OMNI-LCD, and OMNI-KP Keypads.
Supervision is not available for the XK-108.
Log Tamper causes all tampers to be logged. Note that only
some OMNI-LCD and OMNI-KP keypads will report a
keypad tamper. Refer to your keypad instructions to
determine if your keypad has tamper.