Section 6. System Programming
6-27
L3
Entry
AC Dial Delay
(min)
L3
Entry
AC Dial Delay
(min)
L3
Entry
AC Dial Delay
(min)
L3
Entry
AC Dial Delay
(min)
0
random 10–225
4
60
8
120
C
180
1
15
5
75
9
135
D
195
2
30
6
90
A
150
E
210
3
45
7
105
B
165
F
225
UL
Must be programmed as “F” for UL installations.
Q 15, L4: Ring Count
— Enter the digit for the desired ring count (number of rings before the system
picks up the phone line when downloading) from the table below.
L4
Entry
Ring
Count
L4
Entry
Ring
Count
L4
Entry
Ring
Count
L4
Entry
Ring
Count
0
Disabled *
4
4
8
8
C 12
1 1
5
5
9
9
D 13
2 2
6
6
A
10
E
14
3
3
7
7
B
11
F 15
* If ring count is
disabled, the
control cannot be
accessed remotely
(downloading).
QUESTION 16 ENTRY-EXIT DELAY/DIALER DELAY
L1 L2 L3 L4
Entry
Entry
Exit
Abort dial
time 1
time 2
time Delay time
Q 16, L1, L2: Entry Delay
— This question defines entry-exit delay and dialer delay values. Enter the
digit for the desired entry delay in locations L1–L2 as follows.
L1
–
L2
Entry
Entry Delay
(Seconds)
L1
–
L2
Entry
Entry Delay
(Seconds)
L1
–
L2
Entry
Entry Delay
(Seconds)
L1
–
L2
Entry
Entry Delay
(Seconds)
0
1
4
20
8
75
C
150
1
5
5
30
9
90
D
180
2
10
6
45
A
105
E
210
3
15
7
60
B
120
F
240
UL
Must be programmed as “6” for UL installations.
Q 16, L3: Exit Time
— Enter the L3 digit for the desired exit time from the following table.
L3
Entry
Exit Time
(Seconds)
L3
Entry
Exit Time
(Seconds)
L3
Entry
Exit Time
(Seconds)
L3
Entry
Exit Time
(Seconds)
0
256
4
40
8
80
C
120
1
10
5
50
9
90
D
130
2
20
6
60
A
100
E
140
3
30
7
70
B
110
F
150
UL
Must be programmed as “5” for UL installations.