OMNI-400/OMNI-400EU and OMNI-600/OMNI-600EU Installation and Setup Guide
6-20
Q 11, L2
— Enter the L2 digit from the table below.
L2
Entry
Arm
With
Fault
Bypass
Error
Exit
Error
No PC
if
Armed
No Arm
if Low
Battery
0
✔
1
✔
✔
2
✔
3
✔
✔
4
✔
✔
5
✔
✔
✔
6
✔
✔
7
✔
✔
✔
8
✔
✔
9
✔
✔
✔
A
✔
✔
B
✔
✔
✔
C
✔
✔
✔
Arm With Fault: Allows the system to arm even
if a delay or interior zone is faulted. However,
faulted zones must be restored before exit time
expires, or an alarm will result if the bypass
error is not enabled.
Bypass Error/Exit Error: If Bypass Error is
selected, interior and delay zones faulted after
arming will be bypassed and no Exit Error report
will be sent. If Exit Error is selected, when
interior and delay zones are faulted at the end of
the exit time, the system will go into exit error
and a report will be sent if enabled in Submode
1, Question 24, Location 1.
No PC if Armed: If system is armed, the control
will not communicate with downloading
computer.
No Arm if Low Battery: If selected, system
will not arm if a system low battery exists.
D
✔
✔
✔
✔
E
✔
✔
✔
UL
Bypass Error/Exit Error must not be
enabled for UL installations.
F
✔
✔
✔
✔
Q 11, L3 —
Enter the L3 digit from the table below.
L3
Entry
Disable
Arm
Exit
Extends
No AC/
NAK Arm
0
1
✔
2
✔
3
✔
✔
4
✔
5
✔
✔
6
✔ ✔
7
✔ ✔ ✔
Disable Arming: If selected, the system cannot be armed.
Additionally, a report code of “DD” must be defined in Submode
2, Question 30, L1/L2. This code is sent if a user attempts to
arm the system after this option has been set.
Exit Extends: If selected, re-entering the premises during the
exit delay time will restart the exit delay timer, allowing
someone to exit again without having to disarm, then rearm the
system. This can only occur once during an armed period. See
Question 11, L4 for related Quick Exit feature.
No AC/NAK Arm: If selected, when the user tries to arm the
system with an AC fail condition, the system will provide a
negative acknowledgement and will not arm. To arm the
system, the user must enter their code a second time.
UL
Exit Extends must not be enabled for UL installations.