OMNI-400/OMNI-400EU and OMNI-600/OMNI-600EU Installation and Setup Guide
5-10
Quick Command Modes
The end user can perform the following commands (if programmed):
COMMAND
KEYSTROKES DESCRIPTION
Quick Arming
# 1
Will arm the system, if it is ready to arm. Submode 1, Question 11, L4
Quick Forced Arming
# 2
Will bypass all currently faulted zones and arm system. Submode 1,
Question 11, L4
Set Time
# 3
Enter hours, minutes, month, day, and year and if the crystal real-time
clock (RTC) is enabled (Submode 1, Question 10, L2), a crystal
adjustment value. This question may require a user code with an
authority level of 1, 2, or 3, to set the clock based on Installer program.
(Submode 1, Question 13, L2)
Display Zone Directory
(LCD Keypad Only)
# 4
Displays all zones enabled. Always enabled.
Display Time
(LCD Keypad Only)
# 51
Used to verify the real-time clock settings used for CS test, auto-arm and
logging events. Displays hour, minute, month, day, and year. The time is
displayed in either 24 hour or 12 hour format and the date may be
displayed with day or month first, based on programming options in
Submode 1, Question 13, Location 3.
Display Auto-Arm Time
(if auto-arm optioned)
(LCD Keypad Only)
# 52
Displays hour and minute of auto-arm time. This question may require a
user code with an authority level of 1, 2, or 3, based on Installer program.
(Submode 1, Question 13, L2)
View Event Log
(LCD Keypad Only)
# 53
This option is enabled for users in Submode 1, Question 14, L1. If
enabled, the event log may be seen for the system. Additionally, the time
and date display options are adhered to. This means the time may be in
24 hour or 12 hour format, and the date may have either the day or month
displayed first. When the log is viewed through the Quick Command, the
Clear Log function is blocked. Either the [STAY] or the [
✱
] key may be
used to exit this mode. Pressing the [#] key advances to the next valid
entry.
Set Auto-Arm Time
(LCD Keypad Only)
# 54
Enter hour, minutes. This question may require a user code with the
appropriate authority level to set the clock. Submode 1, Question 21.
Display Version
# 55
Displays the revision level of the system software.
Door Strike
# 57
Door strike trigger/relay activation. Enabled for all users if selected in
Submode 1, Question 10, L1.
Change Pager Number
# 58
Lets the user modify the current pager phone number.
Display/Toggle Chime
#6
The LCD keypad will display current state and provide option to toggle the
current state. The LED pads will simply toggle the chime state and beep
once to indicate the state has changed.
Pager Open/Close
enable
#8
Toggles whether open/close reports are to be sent to the pager. Works
same as chime. For user open/close only.
User On-Line Download
#9
Starts remote connect sequence with PC downloader.
Quick Commands are valid for 10 seconds of no activity, unless otherwise stated.