![FBII OMNI-400 EU Скачать руководство пользователя страница 24](http://html1.mh-extra.com/html/fbii/omni-400-eu/omni-400-eu_installation-and-setup-manual_547062024.webp)
OMNI-400/OMNI-400EU and OMNI-600/OMNI-600EU Installation and Setup Guide
5-4
Enabling keypad sounder:
XK-7LC: The 4
th
DIP switch in the keypad controls the sounder on/off.
OMNI-KP/OMNI-LCD: Press and hold the [Code] and [Bypass] keys to toggle the sounder on/off.
The keypad sounder annunciates differently to indicate the following conditions:
Chirp
Keypad sounds a short chirp to confirm each keystroke.
Steady
The keypad makes a steady sound during entry time and/or during burglary
alarm.
Chime
Acknowledge
Steady 1-second tone (SYSTEM DISARMED ONLY). Upon successful entry
of certain commands, the system will sound for approximately half a second.
Pulsing
A pulsing sound (approximately half a second ON, then OFF) indicates a
trouble condition such as AC loss, low battery, or fire trouble.
Negative
Acknowledgment
Upon entry of an illegal command, the keypad sounds four short beeps. For
example, if during an attempt to define a new user the master user is not
entered, four short beeps indicate that the command was unsuccessful.
Sounder
Ringback
Several short beeps to indicate successful communication to the central
station. This occurs for all signals, excluding ambush and silent zones.
Fast Pulsing
Sounder
Sound generated during entry time period AFTER an alarm condition has
occurred and the system reached bell cutoff. A pulsing sounder follows the
bell output on fire conditions. Trouble conditions also generate a pulsing
sounder, and may be silenced through entry of a valid user code.
!
The keypad is NOT operational if none of the LED's are lit and the keypad does not beep when
keys are pressed. This is an indication that service is required. Consult the trouble shooting
section of this manual.
Keypad Addressing
This address will identify the keypad number to the control panel. A maximum of 12 keypads (OMNI-
KP, OMNI-LCD, or XK-7LC) can be identified, but the total of 12 cannot be comprised of more than 8
LCD keypads or 8 fixed-word keypads.
The XK-108 keypad may also be used on the system; however, when the XK-108 is used,
keypad addressing does not apply. Additionally, you cannot use any other type of keypad if you
are using XK-108’s on the system.
Set the OMNI-KP and OMNI-LCD keypad addresses by doing the following (refer to the instructions
provided with the keypads for additional information on setting the keypad addresses):
1. Within 30 seconds of applying power to the unit, press the [CODE] and [STAY] keys at the same
time and hold them for several seconds.
2. When the display shows a single digit pulsing, enter the address 1–8 for fixed-word and for LCD
keypads.
3. To terminate the mode, press [
✱
].
Set the XK-7LC keypad address by using its DIP switches. Refer to the instructions provided with the
keypad for additional information on setting the keypad address.