Section 4. System Configuration
4-3
Connect the Relay Modules as shown:
1
2
3
4
5
6
7
8
9
10 11 12 13 14 15 16 17 18 19 20
GND DATA CLK +12V NO NC
C
NO
NC
C
NO
NC
C
NO
NC
C
NO
NC
C
Relay 1
Relay 2
Relay 3
Relay 4
Relay 5
XL4705
RELAY
MODULE
CONNECT
TO EARTH
GROUND
TO AUX POWER
TERMINALS
CONNECT TO TRIGGER 4
CONNECT TO TRIGGER 3
DATA
CLOCK
12V
REFER TO
“DIP SWITCH ADDRESSING”
TABLE FOR SETTINGS
DIP SWITCHES
DIP SWITCH 1: In the ON position, inverts Relays 2 and 4, e.g.,
if wired for normally closed (N.C.), relay will
change to normally open (N.O.), and vice versa.
SW1
ON
OFF
1 2 3 4
DIP SWITCHES
SHOWN IN “OFF”
POSITION
Trigger Address Switch 2 Switch 3 Switch 4
1–5
OFF
OFF
OFF
6–10
ON
OFF
OFF
DIP SWITCH ADDRESSING
*
Modules may have to be powered from a separate
12V power source if the total current drawn by the
relay modules exceeds the current available from
the control panel’s Auxiliary Power output.
SW1
USE TWISTED
PAIR FOR
THESE WIRES
(4)
(6)
OMNI600-004-V0
XL4705 Current Advisory: Standby
=
16mA
Each active relay = 40mA
Total current drain with all five relays active = 200mA
If a separate power supply is used to power the module, you must
connect the power supply ground to the control panel ground terminal.
Paging Feature
Summary: A 16-digit phone number to dial for paging, which the end user or installer can reprogram,
is entered in Submode 1, Question 04. The number of times the pager number is dialed is installer-
programmable from 1–3 times. The installer also selects which events may cause a page. Four
conditions may be selected: (1) zone alarms, (2) zone troubles, (3) openings, and (4) closings.
Additionally, paging may be turned on or off for opening and closing.
NOTE: Only one event is paged-based on the priority described next.
Paging Alarms, Troubles, Open, and Close:
Alarms take priority over troubles, troubles take priority over opens, and opens take priority over
closes.
For pager opening or closing to occur, the following conditions must exist:
•
The system must not have an alarm or trouble condition.
•
The system must have the open or close enabled (Submode 1, Question 14, L4).