OMNI-400/OMNI-400EU and OMNI-600/OMNI-600EU Installation and Setup Guide
6-32
Code Trigger
Type
Description
00
Disabled
01
Burg Bell no Bell Test
Turns on with the burg bell and off when the bell times out or is shut off.
02
Fire Bell no Bell Test
Follows the same temporal pattern as the fire bell. Turns off when the fire bell
times out or is turned off.
03
System Armed
Is on when the system is armed; otherwise is off.
04
System Ready
Is on when the system is disarmed and ready; otherwise is off.
05
In Entry Delay
Is on if the system is in entry delay; otherwise is off.
06
In Exit Delay
Is on if the system is in exit delay; otherwise is off.
07
Armed Instant
Is on if the system is armed in the instant mode; otherwise is off.
08
Armed Stay
Is on if the system is armed in the stay mode; otherwise is off.
09
Sounder On/Pulsing
Follows either a pulsing sounder or steady sounder.
0A
Chime
Is activated for 1 second if a chime zone is activated.
0B
Line Seize
System trigger is on if the phones are disconnected.
0C
Phone Fail
System trigger is on if the phone line monitor detects that the phone line has
been cut.
0D
AC Loss
System trigger is on when AC loss is detected.
0E
Low Battery
System trigger is on when the battery voltage falls below 10.2 volts.
0F
24-Hr Trouble
On if any 24-hour trouble displayed. Turned off when the loop restores and
clears the display.
10
24-Hr Alarm
On if any 24-hour alarm zone is displayed. Turned off when the alarm display is
cleared. Note that the 24-hour alarm is not generated for any zone set to silent.
11
Instant Zone Faulted
On if any instant zone is faulted.
12
Delay Zone Faulted
On if any delay zone is faulted. This trigger is not generated during entry/exit
delay times.
13
Interior Zone Faulted
On if any interior zone is faulted.
14
Zone Tamper
On if any Tamper has occurred on a zone.
15
Keypad Tamper
On if a keypad tamper has occurred.
16
N/A
Not used.
17
Comm. Fail
On when comm fails occurs, off after code is entered.
18
Key Tamper, Mom. Sec
If 21 keys are entered without a valid code, key tamper activates momentarily
for the number of seconds programmed.
19
Duress Code, Mom. Sec
Momentary output based on seconds. Activated when user code 15 is enabled
for duress (ambush).
1A
Bell Strobe - Internal, No
dings
On with either fire or burg, off with code. The Bell Strobe is not affected by bell
timeout.
1B
Bell Strobe - External, with
dings
With arm/disarm dings. Latches on with either a fire or burg bell, off with code.
The Bell Strobe is not affected by bell timeout.
1C
Trigger Zone, Mom. Minutes Follows the zone type - trigger. Momentary based on minutes.
1D
Trigger Zone, Mom.
Seconds
Follows the zone type - trigger. Momentary based on seconds.
1E
Door Strike, Mom. Seconds
Activates for seconds upon valid user code or user code 10-14 as enabled in
installer programming.