configure syslog add
ExtremeWare XOS 11.0 Command Reference Guide
339
configure syslog add
configure syslog {add} <ipaddress> {vr <vr_name>} [local0 ... local7]
{<severity>}
Description
Configures the remote syslog server host address, and filters messages to be sent to the remote syslog
target.
Syntax Description
Default
If a severity level is not specified, all messages are sent to the remote syslog server target. If a virtual
router is not specified, VR-Mgmt is used.
Usage Guidelines
Options for configuring the remote syslog server include:
•
ipaddress—The IP address of the remote syslog server host.
•
facility—The syslog facility level for local use (local0– local7).
•
virtual router—The virtual router that can reach the syslog host
•
severity—Filters the messages sent to the remote syslog server target to have the selected severity or
higher (more critical). Severities include critical, error, warning, notice, info, debug-summary,
debug-verbose, and debug-data.
The switch log overwrites existing log messages in a wrap-around memory buffer, which may cause
you to lose valuable information once the buffer becomes full. The remote syslog server does not
overwrite log information, and can store messages in non-volatile files (disks, for example).
The
enable syslog
command must be issued in order for messages to be sent to the remote syslog
server(s). Syslog is disabled by default. A total of four syslog servers can be configured at one time.
When a syslog server is added, it is associated with the filter
DefaultFilter
. Use the
configure log
target filter
command to associate a different filter.
The syslog facility level is defined as local0 – local7. The facility level is used to group syslog data.
Example
The following command configures the remote syslog server target with a critical severity:
configure syslog 123.45.67.78 local1 critical
ipaddress
Specifies the remote syslog server IP address.
vr_name
Specifies the virtual router that can reach the server IP address.
local0 ... local7
Specifies the local syslog facility.
severity
Specifies a message severity. Severities include critical, error, warning, notice,
info, debug-summary, debug-verbose, and debug-data.
Содержание ExtremeWare XOS 11.0
Страница 26: ...26 ExtremeWare XOS 11 0 Command Reference Guide Contents...
Страница 176: ...176 ExtremeWare XOS 11 0 Command Reference Guide Commands for Managing the Switch...
Страница 262: ...262 ExtremeWare XOS 11 0 Command Reference Guide VLAN Commands...
Страница 280: ...280 ExtremeWare XOS 11 0 Command Reference Guide FDB Commands...
Страница 492: ...492 ExtremeWare XOS 11 0 Command Reference Guide EAPS Commands...
Страница 536: ...536 ExtremeWare XOS 11 0 Command Reference Guide STP Commands...
Страница 580: ...580 ExtremeWare XOS 11 0 Command Reference Guide ESRP Commands...
Страница 752: ...752 ExtremeWare XOS 11 0 Command Reference Guide IGP Commands History This command was available in ExtremeWare XOS 10 1...
Страница 816: ...816 ExtremeWare XOS 11 0 Command Reference Guide BGP Commands History This command was available in ExtremeWare XOS 10 1...
Страница 876: ...876 ExtremeWare XOS 11 0 Command Reference Guide BGP Commands...
Страница 926: ...926 ExtremeWare XOS 11 0 Command Reference Guide IP Multicast Commands...