206
ExtremeWare XOS 11.0 Command Reference Guide
Commands for Configuring Slots and Ports on a Switch
enable mirroring to port
enable mirroring to port [<port>] [tagged | untagged]
Description
Dedicates a port on the switch to be the mirror output port, or the monitor port.
Syntax Description
Default
Disabled.
Usage Guidelines
Port-mirroring configures the switch to copy all traffic associated with one or more ports to a monitor
port on the switch. The monitor port can be connected to a network analyzer or RMON probe for
packet analysis. The switch uses a traffic filter that copies a group of traffic to the monitor port. The
traffic filter can be defined based on one of the following criteria:
• Physical port
—All data that traverses the port, regardless of VLAN configuration, is copied to the
monitor port.
• VLAN
—All data to and from a particular VLAN, regardless of the physical port configuration, is
copied to the monitor port.
• Virtual port
—All data specific to a VLAN on a specific port is copied to the monitor port.
Up to 16 mirroring filters and one monitor port can be configured on the switch. After a port has been
specified as a monitor port, it cannot be used for any other function. Frames that contain errors are not
mirrored.
NOTE
Beginning with ExtremeWare XOS 11.0, the monitor port must be explicitly configured for tagged or
untagged. Mirroring configurations prior to 11.0 are restored as tagged monitor ports only.
The traffic egressing the monitor port can either be tagged or untagged. If the mirroring is enabled as
tagged on the monitor port, all traffic egressing the monitor port is tagged. In this case, even if some
untagged ports send mirrored traffic to the monitor port, that traffic also egresses the monitor port
tagged. And, if mirroring is enabled as untagged on the monitor port, all traffic egressing the monitor
port is untagged, including mirrored tagged packets.
When you upgrade to 11.0, all restored mirroring configurations are tagged monitor ports only.
port
Specifies the mirror output port.
tagged
Specifies the mirror output, or monitor, port is tagged.
untagged
Specifies the mirror output, or monitor, port is untagged.
Содержание ExtremeWare XOS 11.0
Страница 26: ...26 ExtremeWare XOS 11 0 Command Reference Guide Contents...
Страница 176: ...176 ExtremeWare XOS 11 0 Command Reference Guide Commands for Managing the Switch...
Страница 262: ...262 ExtremeWare XOS 11 0 Command Reference Guide VLAN Commands...
Страница 280: ...280 ExtremeWare XOS 11 0 Command Reference Guide FDB Commands...
Страница 492: ...492 ExtremeWare XOS 11 0 Command Reference Guide EAPS Commands...
Страница 536: ...536 ExtremeWare XOS 11 0 Command Reference Guide STP Commands...
Страница 580: ...580 ExtremeWare XOS 11 0 Command Reference Guide ESRP Commands...
Страница 752: ...752 ExtremeWare XOS 11 0 Command Reference Guide IGP Commands History This command was available in ExtremeWare XOS 10 1...
Страница 816: ...816 ExtremeWare XOS 11 0 Command Reference Guide BGP Commands History This command was available in ExtremeWare XOS 10 1...
Страница 876: ...876 ExtremeWare XOS 11 0 Command Reference Guide BGP Commands...
Страница 926: ...926 ExtremeWare XOS 11 0 Command Reference Guide IP Multicast Commands...