162
P
RODUCT
M
ANUAL
1014258
C
HAPTER
8—T
ROUBLESHOOTING
AND
E
RROR
C
ODES
203
X axis EOT fail.
The library could
not detect the end-of-travel
sensor on the horizontal axis.
Open the door and remove the magazines. Look for
anything that might be obstructing the robot’s path along
the horizontal axis.
Make sure the library and tape drive(s) are not being used
by any host, then reset the library (see
).
If there are no obstructions and the error persists, contact
your service provider.
204
X axis home sensor fail.
The
library could not detect the
horizontal axis home sensor (safe
rotate position).
205
X axis scan failed.
The library
could not complete a move along
the horizontal axis.
207
X axis cal fail.
The robot position
along the horizontal axis could
not be calibrated.
213
Invalid Xcard configuration.
An
invalid combination of expansion
cards is installed in the library.
Make sure the library and tape drive(s) are not being used
by any host, then reset the library (see
).
If the error persists, contact your service provider. An
expansion card may not be properly installed or the wrong
card is installed.
214
Invalid Slot Config.
The
Maximum Number of Slots is set
to 1 and the last slot is configured
as a cleaning slot.
Change the Max Addressable Slot to a value greater than 1
(see
) or turn off the Clean Slot Option (see
).
220
OS failure.
The library’s
operating system experienced an
error.
Make sure the library and tape drive(s) are not being used
by any host, then reset the library (see
).
If the error persists, contact your service provider.
221
Could not set alarm.
The
library’s operating system
experienced an error.
222
OS message failure.
The library’s
operating system experienced an
error.
226
Mbus interrupt timeout.
The
robot command processor timed
out before setting an interrupt.
Make sure the library and tape drive(s) are not being used
by any host, then reset the library (see
).
If the error persists, the robot may need to be replaced.
Contact your service provider.
227
Mbus acknowledge failure.
The
robot command processor failed
to respond to a command.
230
DHCP server timeout.
The
Ethernet DHCP server could not
assign an IP address for the library.
Set the network address to Static and set the desired IP address
(see
Table 8-1
Library error codes (continued)
Code
Description
Corrective Action
Содержание 221L
Страница 1: ...1014258 B EXABYTE 221L AND 221L FC LIBRARIES PRODUCT MANUAL...
Страница 8: ...viii PRODUCT MANUAL 1014258 Notes...
Страница 42: ...26 PRODUCT MANUAL 1014258 CHAPTER 2 INSTALLING THE LIBRARY NOTES...
Страница 68: ...52 PRODUCT MANUAL 1014258 CHAPTER 3 CONFIGURING THE LIBRARY NOTES...
Страница 90: ...74 PRODUCT MANUAL 1014258 CHAPTER 4 OPERATING THE LIBRARY NOTES...
Страница 102: ...86 PRODUCT MANUAL 1014258 CHAPTER 5 VIEWING LIBRARY INFORMATION NOTES...
Страница 154: ...138 PRODUCT MANUAL 1014258 CHAPTER 6 USING THE REMOTE MANAGEMENT UTILITY NOTES...
Страница 168: ...152 PRODUCT MANUAL 1014258 CHAPTER 7 MAINTENANCE NOTES...
Страница 198: ...182 PRODUCT MANUAL 1014258 APPENDIX A LIBRARY SPECIFICATIONS NOTES...