Port VLAN :
Determines the port's VLAN ID (a.k.a. PVID). Allowed VLANs are in the range 1 through
4095,
default
being
1.
On ingress, frames get classified to the Port VLAN if the port is configured as VLAN
unaware, the frame is untagged, or VLAN awareness is enabled on the port, but the frame
is
priority
tagged
(VLAN
ID
=
0).
On egress, frames classified to the Port VLAN do not get tagged if
configuration
is
set
to
untag
Port
VLAN.
The Port VLAN is called an "Access VLAN" for ports in Access mode and Native VLAN for
ports in Trunk or Hybrid mode.
Port Type :
Ports in hybrid mode allow for changing the port type, that is, whether a frame's VLAN tag
is used to classify the frame on ingress to a particular VLAN, and if so, which TPID it reacts
on. Likewise, on egress, the Port Type determines the TPID of the tag, if a tag is required.
Unaware:
On ingress, all frames, whether carrying a VLAN tag or not, get classified to the Port VLAN,
and
possible
tags
are
not
removed
on
egress.
C-Port:
On ingress, frames with a VLAN tag with TPID = 0x8100 get classified to the VLAN ID
embedded in the tag. If a frame is untagged or priority tagged, the frame gets classified to
the Port VLAN. If frames must be tagged on egress, they will be tagged with a C-tag.
S-Port:
On ingress, frames with a VLAN tag with TPID = 0x8100 or 0x88A8 get classified
to the VLAN ID embedded in the tag. If a frame is untagged or priority tagged, the
frame gets classified to the Port VLAN. If frames must be tagged on egress, they
will
be
tagged
with
an
S-tag.
S-Custom-Port:
On ingress, frames with a VLAN tag with a TPID = 0x8100 or equal to the
Ethertype configured for Custom-S ports
get classified to the VLAN ID embedded in
the tag. If a frame is untagged or priority tagged, the frame gets classified to the
Port VLAN. If frames must be tagged on egress, they will be tagged with the
custom S-tag.
Ingress Filtering :
Hybrid ports allow for changing ingress filtering. Access and Trunk ports always have
ingress
filtering
enabled.
If ingress filtering is enabled (checkbox is checked), frames classified to a VLAN that the
port
is
not
a
member
of
get
discarded.
If ingress filtering is disabled, frames classified to a VLAN that the port is not a member of
are accepted and forwarded to the switch engine. However, the port will never transmit
frames classified to VLANs that it is not a member of.
Ingress Acceptance :
Hybrid ports allow for changing the type of frames that are accepted on ingress.
Tagged
and
untagged
both
tagged
and
untagged
frames
are
accepted.
Tagged
Only
Only tagged frames are accepted on ingress. Untagged frames are discarded.
Содержание Cross-8/HPoE-10G
Страница 1: ......
Страница 4: ......
Страница 9: ...19 4 2 Firmware Selection 350 ...
Страница 10: ...Revision History ...
Страница 85: ... Reset Click to undo any changes made locally and revert to previously saved values ...
Страница 111: ...Click to undo any changes made locally and revert to previously saved values ...
Страница 116: ...Click to undo any changes made locally and revert to previously saved values ...
Страница 150: ...Click to refresh the page immediately ...
Страница 295: ...Click to save changes Reset Click to undo any changes made locally and revert to previously saved values ...
Страница 301: ...Buttons Apply Click to save changes Reset Click to undo any changes made locally and revert to previously saved values ...