![Evidence Cross-8/HPoE-10G Скачать руководство пользователя страница 289](http://html1.mh-extra.com/html/evidence/cross-8-hpoe-10g/cross-8-hpoe-10g_user-manual_2445999289.webp)
16-2 Status
This page allows the user to inspect the current
Web Interface
To display the PTP status in the web interface:
1.
Click PTP and Status.
2.
Specify the PTP parameters.
3.
Click Apply to apply the change.
Figure 16-2: The PTP Status
Parameter description:
PTP External Clock Description
One_PPS_Mode :
Shows the current One_pps_mode configured.
Output : Enable the 1 pps clock output
Input : Enable the 1 pps clock input
Disable : Disable the 1 pps clock in/out-put
External Enable :
Shows the current External clock output configuration.
True : Enable the external clock output
False : Disable the external clock output
Adjust Method :
Shows the current Frequency adjustment configuration.
LTC : Use Local Time Counter (LTC) frequency control
Single : Use SyncE DPLL frequency control, if allowed by SyncE
Independent : Use an oscillator independent of SyncE for frequency control, if supported by
the HW
Common : Use second DPLL for PTP, Both DPLL have the same (SyncE recovered) clock.
Содержание Cross-8/HPoE-10G
Страница 1: ......
Страница 4: ......
Страница 9: ...19 4 2 Firmware Selection 350 ...
Страница 10: ...Revision History ...
Страница 85: ... Reset Click to undo any changes made locally and revert to previously saved values ...
Страница 111: ...Click to undo any changes made locally and revert to previously saved values ...
Страница 116: ...Click to undo any changes made locally and revert to previously saved values ...
Страница 150: ...Click to refresh the page immediately ...
Страница 295: ...Click to save changes Reset Click to undo any changes made locally and revert to previously saved values ...
Страница 301: ...Buttons Apply Click to save changes Reset Click to undo any changes made locally and revert to previously saved values ...